Tank-type Metal Oxide Surge Arresters for GIS

  • Tank-type Metal Oxide Surge Arresters for GIS

Key attributes

Brand ROCKWILL
Model NO. Tank-type Metal Oxide Surge Arresters for GIS
Rated voltage 200kV
Rated frequency 50/60Hz
Series Y10WF

Product descriptions from the supplier

Description

Description

Tank-type Metal Oxide Surge Arresters for GIS are key protective devices specially designed for Gas Insulated Switchgear (GIS). They adopt a tank-type sealed structure and integrate high-performance Metal Oxide Varistors (MOV) internally, which can effectively suppress transient overvoltages caused by lightning, operating overvoltages, etc. in GIS systems. The arrester is directly installed inside GIS equipment. By quickly conducting surge currents to the ground terminal and clamping the voltage to a safe level, it protects core components in GIS such as circuit breakers, disconnectors, and busbars from overvoltage damage, ensures the stable and safe operation of the entire GIS system, and significantly reduces the risk of equipment failure and power outages.

Features

  • High Adaptability to GIS Systems: Specifically designed for GIS equipment, its size and interfaces perfectly match the GIS system, enabling seamless integration into compact GIS cabinets without occupying extra space, thus meeting the installation requirements of miniaturization and integration of GIS equipment.

  • Advantages of Tank-type Sealed Structure: Adopting a metal tank-type sealed design, it has extremely strong airtightness and mechanical strength, which can effectively isolate interference from dust, moisture, dirt, etc. in the external environment. It is suitable for various harsh environments such as high altitude, humidity, and heavy dust, ensuring the long-term stable operation of the arrester.

  • Excellent Overvoltage Suppression Capability: The built-in Metal Oxide Varistor (MOV) has excellent nonlinear volt-ampere characteristics. When an overvoltage occurs, it can respond quickly, rapidly absorb and release huge surge energy, and limit the overvoltage within the tolerance range of GIS equipment, with remarkable protection effect.

  • Low Energy Loss and Long Service Life: In normal operation, the MOV is in a high-resistance state, with extremely small leakage current and low energy loss, reducing unnecessary waste of electrical energy. At the same time, its material has high stability and strong anti-aging performance, with a long service life, reducing maintenance and replacement costs.

  • Safe and Reliable Operation Guarantee: It has good thermal stability and short-circuit resistance. When encountering extreme overvoltage or short-circuit faults, it can withstand short-term large current impacts without dangerous situations such as explosion, providing reliable guarantee for the safe operation of the GIS system.

  • Compliance with International Standards and Specifications: It is designed and manufactured in strict accordance with relevant international and domestic standards such as IEC and GB, and has passed a series of stringent electrical performance and environmental adaptability tests, ensuring that its performance indicators meet the high requirements of the GIS system and have wide applicability and interchangeability.

 

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

kV

kV

kV

kV

kV

kV

kV

A

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times





(Peak Value

(Peak Value

(Peak Value

(Peak Value

Y10WF1-90/232

90

66

72.5

130

198

232

266

600

Y10WF1-96/238

96

66

75

140

207

238

268

800

Y10WF1-100/260

100

110

78

145

221

260

291

600

Y10WF1-108/281

108

110

84

157

235

281

295

600

Y10WF1-100/260

100

110

73

145

221

260

291

800

Y10WF1-100/260

100

110

73

145

221

260

291

800

Y10WF1-100/260

100

110

78

145

221

260

291

600

Y10WF1-90/232

90

66

72.5

130

198

232

266

600

Y10WF1-96/238

96

66

75

140

207

238

268

600

Y10WF1-100/260

100

110

78

145

221

260

291

600

Y10WF1-108/281

108

110

84

157

235

281

295

600

Y10WF1-200/520

200

220

146

290

442

520

582

800

Y10WF1-200/520

200

220

146

290

442

520

582

800

Y10WF1-420/1046

420

550

318

565

858

1046

1137

2000

Y10WF1-444/1106

444

550

324

597

907

1106

1238

2000

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.