Three-phase Generator Circuit Breaker 24kV

  • Three-phase Generator Circuit Breaker 24kV

Key attributes

Brand ROCKWILL
Model NO. Three-phase Generator Circuit Breaker 24kV
Rated voltage 24kV
Rated normal current 6900A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series HVS
Description
The Rockwill three-phase generator circuit breaker is designed for installation between the generator and the step-up transformer in power plants. It provides a compact, reliable solution for generator control and protection in utility and industrial generation facilities.

The breaker employs proven arc-quenching technology with a robust operating mechanism to handle the demanding switching duties of generator applications, including frequent start-stop cycles and load rejection. Its open, accessible design facilitates inspection and maintenance, while the integrated disconnecting and earthing functions reduce the overall footprint within the power plant auxiliary system. 

Key Features

  • Compact open design : Minimal footprint for integration into existing power plant layouts and retrofit projects
  • Integrated switching functions: Combines circuit-breaking, disconnecting, and earthing in a single unit
  • High continuous current rating : Suitable for generators up to the medium-output range at 24 kV class
  • High short-circuit capability : Rated to withstand the fault levels typical of generator-fed systems
  • Robust operating mechanism : Designed for frequent switching operations including pumped-storage duty cycles
  • Proven arc-quenching technology : Reliable current interruption under all fault and normal switching conditions
  • Flexible busbar connection : Adaptable to open busbar configurations common in auxiliary power systems

Technical Parameters

Parameter Value
Rated voltage (Ur) 24 kV
Rated normal current (Ir) 6900 A
Rated short-circuit breaking current (Isc) 63 kA
Rated peak withstand current 160 kA
Rated short-time withstand current (3 s) 63 kA
Rated frequency 50 / 60 Hz
Insulation level (Um / PF / BIL) 24 / 50 / 125 kV

Applications

  • Generator main circuit protection and control in thermal, hydro, and gas-turbine power plants
  • Retrofit replacement of existing generator circuit breakers in aging power stations
  • Pumped-storage hydropower plants requiring frequent switching operations
  • Industrial cogeneration and combined-cycle plants with medium-output generators
  • Open busbar auxiliary power systems in utility and industrial generation

Custom ratings (voltage, current, breaking capacity) available on request. Contact Rockwill for application-specific design and quotation.

Documentation Resource Library circuit-breakers

Public.
Rockwill Electric Group Profile
Brochure
English

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register