Universal relay with base HH54P MY4 electromagnetic relay

  • Universal relay with base HH54P MY4 electromagnetic relay

Key attributes

Brand Switchgear parts
Model NO. Universal relay with base HH54P MY4 electromagnetic relay
Rated voltage AC220V
Series HH54P

Product descriptions from the supplier

Description

HH54P is an electromagnetic intermediate relay that focuses on multi contact control and adapts to complex circuits. It is designed specifically for industrial automation production lines, large electromechanical equipment, intelligent distribution systems, and other scenarios. Its core functions include "multi signal synchronous transfer", "complex control circuit expansion", and "strong and weak electrical isolation protection", which can effectively improve the control efficiency and safety of electrical systems under multiple load conditions. It is the preferred component for control circuits of medium and large equipment. ​
1. Structural design: Multi contact layout for convenient installation
Appearance and size: It adopts an opaque flame-retardant shell (some models can choose transparent ones), integrates 4 sets of independent contacts inside, has a compact structure (size about 30 × 22 × 38mm), realizes multi circuit control in limited space, and is suitable for high-density control cabinets and PCB board layouts. ​
Installation method: Supports two mainstream installation forms - one is direct soldering of PCB board to adapt to fixed circuit design; The second is to install it with a dedicated base (such as PYF14A base) buckle for easy maintenance and replacement in the later stage, meeting the needs of batch assembly and maintenance. ​
2. Core performance: Multi loop compatibility, low power consumption, high stability
Contact configuration: Designed with 4 sets of conversion contacts (4c), each set of contacts has a rated working current of 5A and can simultaneously meet the independent switching of 4 loads below AC240V/DC28V; The contact material is high-purity silver alloy, with an initial contact resistance of ≤ 50m Ω and strong arc resistance, effectively reducing contact losses during multi circuit switching and extending service life. ​
Coil characteristics: Provides a wide range of voltage specifications, including DC12V/DC24V/DC48V, AC110V/AC220V/AC380V, suitable for different power supply systems; The coil suction voltage is low (AC ≤ 80% rated voltage, DC ≤ 75% rated voltage), the reset voltage is stable (AC ≥ 30% rated voltage, DC ≥ 10% rated voltage), and the power consumption is controlled within AC1.5VA/DC1.2W to avoid coil overheating during long-term operation. ​
Response and lifespan: Action time ≤ 25ms, reset time ≤ 20ms, able to quickly respond to multi signal synchronous control requirements; The mechanical lifespan is over 50 million cycles (AC)/100 million cycles (DC), and the electrical lifespan is up to 300000 cycles (AC200V 10A L load), maintaining stable performance even in multi circuit high-frequency switching scenarios. ​

3. Safety and Adaptation: Compatible with all scenarios and certified with high specifications
Safety certification: Through international and domestic authoritative certifications such as CCC, UL, CSA, T Ü V, etc., it complies with RoHS environmental standards, eliminates harmful substances such as lead and mercury, and can be safely applied to high-end equipment and export scenarios at home and abroad. ​
Environmental tolerance: Operating temperature range -25 ℃~+60 ℃ (no condensation/freezing), voltage withstand between coil and contact is AC2000V (1 minute), voltage withstand between contact gap is AC1000V (1 minute), with excellent resistance to temperature and humidity changes and electromagnetic interference, suitable for complex environments such as industrial workshops and outdoor distribution rooms. ​
Whether it is a production line with synchronous control of multiple motors or a distribution system with multi circuit protection, HH54P provides reliable support for the control circuits of medium and large electrical equipment with the advantages of "efficient switching of multiple contacts, stable operation with low losses, and strong adaptability for easy maintenance".

Dimension 27.3x21x35
Electric contact 4C.4H.4D
Electric load 5A
Switching Voltage 240VAC/28VDC
Contact Silver alloy
Coil power DC 0.9W AC 1.2VA
Coil voltage DC3V-220V,AC 3V-380V
Electrical life ≥10⁵
Installation PCB printing plate, base
Certification CQC CE
load current 7A
load voltage 300V
medium pressure 2500V AC/S
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.