XTL-HQ1 1-10kW Wind Turbine Generator

  • XTL-HQ1 1-10kW Wind Turbine Generator

Key attributes

Brand Wone Store
Model NO. XTL-HQ1 1-10kW Wind Turbine Generator
Rated power 125kW
Series XTL

Product descriptions from the supplier

Description

Description

The XTL-HQ1 Wind Turbine Generator (1-10KW) is a high-performance renewable energy solution, certified by ISO9001, ISO14001, and EU CE, meeting global quality and environmental standards. With an adjustable power range of 1-10KW, it’s engineered to withstand harsh conditions—strong winds, extreme temperatures, and dusty environments—operating stably with minimal maintenance, reducing long-term costs.

 

Versatile for scenarios like rural communities, industrial workshops, medium-sized farms, and remote communication hubs, it delivers reliable independent power. Sold in over 60 countries across Europe, America, and Oceania, it efficiently harnesses wind energy, adapts to diverse power demands, integrates with landscapes, and is trusted globally for durability and eco-friendliness.

Unit characteristics

  • security:Vertical blades are used, and the main stress points are concentrated in the hub, so the problems of blade falling, fracture and blade flying out are well solved. The horizontal rotation and vertical flat blade principle make it less wind pressure and can resist super typhoons of 45 meters per second.

  • Noise reduction design:The horizontal plane rotation and the blade application aircraft wing principle are used to design the noise to a level that cannot be measured in the natural environment.

  • Turning radius:Due to its different design structure and operating principle, it has a smaller turning radius than other forms of wind power generation, saving space and improving efficiency.

  • Power generation curve characteristics:The starting wind speed is lower than that of other forms of wind turbines, and the increase in power generation is relatively gentle, so in the range of 5~8 meters, its power generation is 10%~30% higher than that of other types of wind turbines.

  • Greater power generation:Take advantage of the wind speed range. The special control principle is used to expand its suitable operating wind speed range to 2.5~25m/s, which maximizes the use of wind resources while obtaining a larger total power generation and improving the economy of wind power equipment.

  • Brake device:The blades themselves have speed protection, and can be equipped with mechanical manual and electronic automatic brakes, and in areas without typhoons and super gusts, only manual brakes need to be set.

Technical specifications

Model

           XTL-HQ1-1KW

XTL-HQ1-2KW

            XTL-HQ1-3KW

            XTL-HQ1-4KW

XTL-HQ1-5KW

XTL-HQ1-10KW

Rated power

1KW

2KW

3KW

4KW

5KW

10KW

Max power

1.5KW

2.5KW

3.5KW

5KW

6KW

12KW

Nominal voltage

96V/120V

96V/120V

96V/120V

120V/220V

120V/220V

220V/380V

Start-up wind speed

2.5m/s

2.5m/s

2.5m/s

2.5m/s

2.5m/s

2.5m/s

Rated wind speed

12m/s

12m/s

12m/s

12m/s

12m/s

12m/s

Survival wind speed

40m/s

40m/s

45m/s

45m/s

45m/s

45m/s

Top net weight

120KG

180KG

220KG

280KG

350KG

960KG

Wind wheel diameter

1.5m

1.67 m

2.1 m

2.3 m

2.63 m

4.8 m

Number of blades

3 tablets/5 tablets

Blades material

aluminium alloy

Fuselage material

8A3 carbon steel

Generator

Three phase ac permanent magnet generator/Maglev generators

Control System

electric eddy brake

Yaw Mode

The wind Angle automatically

Lubrication mode

self-lubricating 

Tower form

Cable/freestanding pylon

Working temperature

-40℃-80℃

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.