YQ&YZ&YC Series Rubber Sheath Flexible Cable

  • YQ&YZ&YC Series Rubber Sheath Flexible Cable
  • YQ&YZ&YC Series Rubber Sheath Flexible Cable
  • YQ&YZ&YC Series Rubber Sheath Flexible Cable

Key attributes

Brand Wone
Model NO. Rubber sheath flexible calbe for communication 300V/750V
Rated voltage 17kV
Rated insulation voltage 16
type Distribution
Series YQ&YZ&YC

Product descriptions from the supplier

Description

Executive standard

GB/T5013-2008 JB8735-1998 Q/YL10-2008

usage

This product is suitabel for rated ac voltage 450/750V or below domestic appliaces, power-operated tools and various portable electric equipments.

Exploitation conditions

a.Rated voltage Uo / U: 

    YQ, YQW type 300/300V, 

    YZ, 60245IEC 53 (YZ)-type 300/500V

    YZW, 60245IEC 57 (YZW) type 300/500V

    YC, YCW, 60245IEC 66 (YCW) type 450/750V

b.Long time allow working temperature of wire core is not more than 65 .

c.W model cable has the property of durability and suitable for cutdoor touching of greasy dirt.

model name and usage

通用橡皮电缆用途.png

Size,weight and technological date

300/300V YQ,YQW  light model

300V YQ YQW.png

300/500V 60245IEC53(YZ),YZ;60245IEC 57(YZW),YZW300 500V YZ YZW.png

450/750V 60245IEC 66(YCW),YCW;YC450 750V YC YCW.png

Current-carrying energy

General purpose rubber sheathed flexible cable carrying capacity通用橡皮电缆载流表.png

Exchange coefficient of rate of different surrounding temperature通用橡皮电缆载流表温度系数.png


Q: What is the difference between YQ, YZ and YC cables? 

A: YQ cable is a light rubber sheath flexible cable, it is relatively light, suitable for light mobile electrical equipment; YZ cable is a medium-sized rubber sheath flexible cable, its performance between YQ and YC, can withstand a certain external mechanical force; YC cable is a heavy rubber sheath flexible cable, its rubber layer is thicker, can withstand greater mechanical external force, more suitable for use in harsh environments. 

Q: What are their respective application scenarios? 

A: YQ cables are often used for low-power, high-flexibility equipment, such as small desk lamps and other small mobile electrical power lines. YZ cable is suitable for connecting cables of some power tools with moderate power, such as electric drills. YC cable is mainly used in large, need to move frequently and the working environment is harsh equipment, such as high-power power tools on construction sites, mining machinery and other power supply connection cables. 

Q: How do you distinguish between these three types of cables? 

A: It can be distinguished from the appearance, thickness and identification of the cable. In general, YC cable is the thickest, YZ is second, and YQ is the thinnest. And there is usually a clear sign on the cable indicating its model number.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.