Why are charges accumulated in the sharpen region of a conductor?

Encyclopedia
10/29/2024

The phenomenon of charges accumulating in sharp regions of a conductor can be explained using several fundamental principles of electrostatics. Here is a detailed explanation:

1. Relationship Between Electric Field Strength and Curvature Radius

On the surface of a conductor, electric field lines must be perpendicular to the surface. This means that at any point on the conductor's surface, the electric field strength 

E is inversely proportional to the curvature radius 

R. Mathematically, this can be expressed as:

E∝ 1/R

In sharp regions, the curvature radius 

R is small, so the electric field strength 

E is large. Conversely, in flat or smooth regions, the curvature radius 

R is large, and the electric field strength E is small.

2. Relationship Between Charge Density and Electric Field Strength

According to Gauss's law, the charge density σ on the surface of a conductor is directly proportional to the electric field strength 

E:σ∝E

Since the electric field strength is greater in sharp regions, the charge density in these areas is also higher. This means that more charges accumulate in sharp regions.

3. Minimization of Potential Energy

The electric field inside a conductor is zero, so the potential on the surface of the conductor is uniform. To achieve this state, charges redistribute on the surface of the conductor to minimize the overall potential energy of the system. In sharp regions, charges tend to concentrate because the strong electric field in these areas effectively repels other charges, thereby reducing the system's potential energy.

4. Distribution of Electric Field Lines

On the surface of a conductor, electric field lines must be perpendicular to the surface. In sharp regions, where the curvature radius is small, the electric field lines are more concentrated, which further leads to the accumulation of charges. In contrast, in flat or smooth regions, the electric field lines are more spread out, resulting in lower charge density.

5. Practical Example: Corona Discharge

Corona discharge is a typical example of charge accumulation in sharp regions. When the sharp part of a conductor accumulates enough charge, the electric field strength becomes very high, sufficient to ionize the surrounding air molecules, leading to corona discharge or spark discharge. This phenomenon is common in high-voltage transmission lines, lightning rods, and other similar devices.

Summary

The reasons why charges accumulate in sharp regions of a conductor include:

  • Electric field strength is inversely proportional to curvature radius: In sharp regions, the curvature radius is small, and the electric field strength is high.

  • Charge density is directly proportional to electric field strength: Regions with high electric field strength have high charge density.

  • Minimization of potential energy: Charges tend to concentrate in sharp regions to minimize the overall potential energy of the system.

  • Distribution of electric field lines: Electric field lines are more concentrated in sharp regions, leading to charge accumulation.

  • These principles work together to cause charges to accumulate in the sharp regions of a conductor, resulting in the observed phenomenon.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
The insulation parameters of the power grid to ground are measured by the tuning method
The insulation parameters of the power grid to ground are measured by the tuning method
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
Effect of Transition Resistance at the Grounding Point on the Rising Speed of Zero - sequence Voltage
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!