What are grid system faults?

Encyclopedia
Field: Encyclopedia
0
China

Types of Faults in Power Grid Systems

Power grid system failure refers to various abnormal conditions that occur in the power system. These faults may affect the normal operation of the power system, leading to equipment damage, power outages, and other issues. The following are several common types of faults in power grids:

1. Short circuit fault

Short circuit fault refers to the phenomenon in which the impedance between conductors of different phases in a power system, or between a conductor and the ground, is significantly reduced, resulting in a sharp increase in current. Short circuit faults can be divided into two types: symmetrical short circuit and asymmetrical short circuit.

  • Symmetric Short Circuit:A fault that involves all three phases is called a symmetrical short circuit. This type of fault maintains the balance of the system and mainly occurs at the terminals of the generator.

  • Asymmetric Short Circuit:A short-circuit fault involving only one phase or two phases is called an asymmetric short circuit. This type of fault causes the system to lose balance and is the most common type of short circuit fault.

2. Phase Failure

Open-phase fault refers to the situation in which one or more phases are disconnected in a power system, leading to asymmetric operation of the system and affecting the normal functioning of equipment.

  • One phase is disconnected:A short circuit between a single phase conductor and ground is the most common type of short circuit fault in an electrical system.

  • Two-phase disconnection:A short circuit between two-phase conductors can also cause an unbalanced condition in the system.

3. Open Circuit Fault

An open-circuit fault refers to a failure in one or more conductors that results in the interruption of a circuit, preventing the normal flow of current. Open-circuit faults can affect the reliability of a system and are commonly known as series faults.

4. Resonance Failure

Resonant faults are generated by resonant circuits composed of inductors, capacitors, and other components in power systems, and can be divided into three types: linear resonance, nonlinear resonance, and parametric resonance.

  • Linear Resonance:The resonance phenomenon generated by the resonant circuit composed of linear elements such as inductors and capacitors.

  • Nonlinear Resonance:Resonance phenomena caused by nonlinear elements (such as ferromagnetic elements) may lead to overvoltage or overcurrent.

  • Parameter Resonance:Resonance phenomena caused by changes in power system parameters (such as frequency, voltage, etc.).

5. Ground Fault

A ground fault refers to an unintended low-impedance connection between a phase conductor in an electrical power system and the ground, which can lead to insulation damage of equipment and increase the risk of failure.

6. Failures caused by natural disasters

Natural disasters such as lightning strikes, heavy rain, strong winds, earthquakes, and floods can also cause damage to power systems, leading to faults.

Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
Understanding Transformer Neutral Grounding
I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
01/29/2026
Voltage Imbalance: Ground Fault, Open Line, or Resonance?
Single-phase grounding, line break (open-phase), and resonance can all cause three-phase voltage unbalance. Correctly distinguishing among them is essential for rapid troubleshooting.Single-Phase GroundingAlthough single-phase grounding causes three-phase voltage unbalance, the line-to-line voltage magnitude remains unchanged. It can be classified into two types: metallic grounding and non-metallic grounding. Inmetallic grounding, the faulted phase voltage drops to zero, while the other two phas
11/08/2025
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
10/09/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.