Calculation of power consumption of 12-volt battery charging for one hour

Encyclopedia
09/23/2024

Related concepts


  • Battery capacity and charging current: When the 12V battery is normally charged (non-fast charging), the current is 10%-20% of the battery capacity, and the best charging current is 10% of the battery capacity. For example, a common 12V60Ah battery has a charging current of 6A (60Ah×10%) 6.



  • Power calculation: According to the formula P=UI (P is power,U is the voltage,I is current), power when a 12-volt battery is charged at 6A current twelve ,P=12V x 6A=72W.



Second, the situation of different capacity batteries


Assume that the battery capacity is 60Ah


Calculation of power consumption for one hour of charging: P=72W=0.072Kw,W=Pt (W is electrical energy,t is time), one hour of charging power consumption.W=0.072kW×1h=0.072 degrees. However, this is the ideal state of calculation, the actual charging efficiency is not 100%, if the charging efficiency is 75%, the actual power consumption is 0.072÷75%=0.096


For other capacity 12 volt batteries


If the battery capacity is 48AH, the charging current is 4.8A (48AH x 10%), power,P=12V×4.8A=57.6W=0.0576kW, the ideal charging one hour power consumption W=0.0576kW×1h=0.0576 degrees. The actual power consumption increases when the charging efficiency is taken into account.


Factors affecting power consumption


  • Charging current size: The higher the charging current, the greater the power, the higher the power consumption in the same time. However, excessive charging current may affect battery life, and it is generally not recommended to exceed 30% of the battery capacity.


  • Charging efficiency: Different chargers have different charging efficiency, which will also affect the actual power consumption. For example, some high-quality chargers may have a charging efficiency of 80%-90%, while some low-quality chargers may have a charging efficiency of only 60%-70%.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Biot Savart Law?
What is Biot Savart Law?
The Biot-Savart Law is employed to determine the magnetic field intensity dHnear a current-carrying conductor. In other words, it describes the relationship between the magnetic field intensity generated by a source current element. This law was formulated in 1820 by Jean-Baptiste Biot and Félix Savart. For a straight wire, the direction of the magnetic field adheres to the right-hand rule. The Biot-Savart Law is also referred to as Laplace’s law or Ampère’s law.Conside
Edwiin
05/20/2025
What is Peak Inverse Voltage (PIV)?
What is Peak Inverse Voltage (PIV)?
DefinitionThe maximum value of the reverse voltage that a PN junction or diode can withstand without damage is termed thePeak Inverse Voltage (PIV). This PIV rating is specified and explained in the datasheet provided by the manufacturer.However, if the voltage across the junction under reverse bias exceeds this specified value, the junction will be damaged.As shown in the figure above, a PN junction or diode is commonly used as a rectifier, i.e., to convert alternating current (AC) to direct cu
Edwiin
05/19/2025
What is Magnetoresistor?
What is Magnetoresistor?
Definition: When the resistance of certain metals and semiconductor materials changes in the presence of a magnetic field, this phenomenon is referred to as the magnetoresistance effect. The components that exhibit this effect are called magnetoresistors. Put simply, a magnetoresistor is a type of resistor whose resistance value fluctuates with the strength and direction of an external magnetic field.Magnetoresistors play a crucial role in detecting the presence of a magnetic field, measuring it
Encyclopedia
05/10/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!