Whether AC circuit breaker can be used for DC circuit ?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

AC circuit breakers (AC circuit breakers) are mainly used to protect devices in AC circuits from overload, short circuit, or ground faults. However, if an AC circuit breaker is to be used in a direct current circuit (DC circuit), several key factors need to be considered:


Type of circuit breaker


  •   AC circuit breaker (AC) : Circuit breakers designed for AC power rely on the natural zero crossing of AC power when cutting off current. Alternating current has two zero crossing points in each cycle, which helps to break the arc and extinguish the arc.


  • Direct current circuit breaker (DC) : There is no natural zero crossing of direct current, so the circuit breaker must be able to cut off the current at any point in time, and special arc extinguishing technology is required to prevent the continuous burning of the arc.


Arc breaking capacity


  • Ac circuit: When the AC circuit breaker cuts off the current, the arc will be naturally extinguished at each zero crossing, which helps the circuit breaker cut off the current.



  • Direct current circuit: DC circuit breakers need to be designed with a special arc extinguishing mechanism, because there is no natural zero crossing in direct current, the arc is not easy to be extinguished, which may lead to equipment damage.


Design variance


  • Arc extinguishing technology: AC circuit breakers usually use simple arc extinguishing technology, such as magnetic blowout or air blast.



  •   Dc circuit breakers: More sophisticated interrupter techniques may be required, such as a vacuum interrupter, SF6 gas (sulfur hexafluoride) interrupter, or other interrupter techniques specifically designed for direct current.


Operating characteristics


  • Current waveform: AC circuit breakers are designed to take into account the waveform of alternating current, while DC circuit breakers take into account the characteristics of direct current.



  • Time-current characteristics (TCC) : The time-current characteristics of AC circuit breakers may not be suitable for the requirements of direct current circuits.


Specifications and standards


  • Ratings: AC circuit breakers and DC circuit breakers have different ratings, including rated current, rated voltage, and breaking capacity.



  • Standards: AC circuit breakers and DC circuit breakers comply with different international or national standards, such as IEC, UL, etc.


Application scenario


  • Ac circuit: AC circuit breaker is suitable for household appliances, industrial motors, lighting systems and other AC circuits.



  • Direct current circuit: DC circuit breaker is suitable for solar system, electric vehicle, communication equipment, data center and other direct current circuit.


Feasibility


In principle, AC circuit breakers are not recommended for direct current circuits, because their design and working principle do not match the characteristics of direct current. Using AC circuit breakers to protect the DC circuit may cause the following problems:


  • Failure to extinguish arc: The current cannot be effectively cut off, resulting in persistent arc.



  • Equipment damage: Failure to turn off the current properly may result in overheating or damage to the equipment.



  • Safety risk: Increased risk of fire and electric shock.


Suggestion


For direct current circuits, it is recommended to use a circuit breaker specifically designed for direct current (DC circuit breaker) to ensure the safe and reliable operation of the equipment.


Sum up


Ac circuit breakers are usually not suitable for direct current circuits because their design and working principle do not match the characteristics of direct current. If you need to use a circuit breaker in a direct current circuit, choose a circuit breaker designed for direct current.


Give a tip and encourage the author!
Recommended
What are the causes of dielectric withstand failure in vacuum circuit breakers?
What are the causes of dielectric withstand failure in vacuum circuit breakers?
Causes of Dielectric Withstand Failure in Vacuum Circuit Breakers: Surface contamination: The product must be thoroughly cleaned before dielectric withstand testing to remove any dirt or contaminants.Dielectric withstand tests for circuit breakers include both power-frequency withstand voltage and lightning impulse withstand voltage. These tests must be performed separately for phase-to-phase and pole-to-pole (across the vacuum interrupter) configurations.Circuit breakers are recommended to be t
Felix Spark
11/04/2025
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
The 8-Phase Guide to Installing LW25-126 High-Voltage Circuit Breakers Correctly
The 8-Phase Guide to Installing LW25-126 High-Voltage Circuit Breakers Correctly
1. Pre-Installation PreparationsBefore commencing installation work, the following preparatory steps must be completed: Organization and Training: Organize training sessions for all construction personnel on relevant regulations,technical standards, and construction procedures. Special emphasis should be placed on safety protocols. Site Survey: Examine the intended location of the circuit breaker, its foundation, and the layout of surrounding equipment and wiring to prevent accidental contact wi
James
10/29/2025
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.