• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


What are Induction Type Meters?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Induction Type Meters Definition


Induction type meters are devices used to measure electrical energy in homes and industries by using the interaction of fluxes and alternating currents.


Working Principle


The working principle and construction of an induction type meter are simple and easy to understand, making them popular for measuring energy in homes and industries. In all induction meters, two fluxes are produced by different alternating currents on a metallic disc. These alternating fluxes create an induced emf. This emf interacts with the alternating current on the opposite side, producing torque.

 

e5e8c0dd4f71a68d62b6fa7427e218f2.jpeg

 

Similarly, the emf produced at point two interacts with the alternating current at point one, creating torque in the opposite direction. These opposing torques cause the metallic disc to move.


This is basic principle of working of an induction type meters. Now let us derive the mathematical expression for deflecting torque. Let us take flux produced at point one be equal to F1 and the flux and at point two be equal to F2. Now the instantaneous values of these two flux can written as:

 

c09ecd783d0937d5849ce40e0d857f8d.jpeg

 

Where, Fm1 and Fm2 are respectively the maximum values of fluxes F1 and F2, B is phase difference between two fluxes.We can also write the expression for induced emf’s at point one be at point two.

 

44410a8df3f089811abdc289cb3f9f5e.jpege226d8cc7530219885d00e3d3d8b24b1.jpeg

 

Where, K is some constant and f is frequency.Let us draw phasor diagram clearly showing F 1, F2, E1, E2, I1 and I2. From phasor diagram, it clear that I1 and I2 are respectively lagging behind E1 and E2 by angle A.

 

c384617f9ccaea438330e8f3b42d3f19.jpeg

 

The angle between F1 and F2 is B. From the phasor diagram the angle between F2 and I1 is (90-B+A) and the angle between F1 and I2 is (90 + B + A). Thus we write the expression for deflecting torque as,Similarly the expression for T d2 is



 

9d3f9fe1bafd23464eecf16477fb3cc7.jpeg

 



The total torque is T d1 – Td2, on substituting the the value of Td1 and Td2 and simplying the expression we get

 

a3dc84faa1ad9cb3e5606dbd40bdcb3a.jpeg

 

 

Types of Induction Meters


The two main types are single phase and three phase induction meters.

 

Which is known as the general expression for the deflecting torque in the induction type meters. Now there are two types of induction meters and they are written as follows:

 

8d25fa35c0f4a139cbed109c0786474c.jpeg

 

  • Single phase type

  • Three phase type induction meters.

 

f2190b7fd2ce49776bdaaa4b5bb5b70d.jpeg

8b535b74c710d6b494c0c538dbdfcdb8.jpeg

 

Single Phase Meter Components


Key parts include the driving system with electromagnets, a floating aluminum disc in the moving system, a braking system with a permanent magnet, and a counting system to record revolutions.


Advantages


  • They are inexpensive as compared to moving iron type instruments.



  • They have high torque is to weight ratio as compared to other instruments.



  • They retain their accuracy over wide range of temperature as well as loads.


Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.