What is the Measurement of Resistance?


Resistance Definition


Resistance is the opposition to electric current flow, a fundamental concept in electrical engineering.


Measurement of Low Resistance (<1Ω)


7a7a19eb4b5ba297fc1f385865250ab0.jpeg


Kelvin’s Double Bridge


Kelvin’s double bridge is a modification of simple Wheatstone bridge. Figure below shows the circuit diagram of Kelvin’s double bridge.


As we can see in the above figure there are two sets of arms, one with resistances P and Q and other with resistances p and q. R is the unknown low resistance and S is a standard resistance. Here r represents the contact resistance between the unknown resistance and the standard resistance, whose effect we need to eliminate. For measurement we make the ratio P/Q equal to p/q and hence a balanced Wheatstone bridge is formed leading to null deflection in the galvanometer. Hence for a balanced bridge we can write


By substituting Equation 2 into Equation 1 and using the ratio P/Q = p/q, we derive the following result:


Hence we see that by using balanced double arms we can eliminate the contact resistance completely and hence error due to it. To eliminate another error caused due to thermo-electric emf, we take another reading with battery connection reversed and finally take average of the two readings. This bridge is useful for resistances in range of 0.1µΩ to 1.0 Ω.


5ec8065890e5bc34ba7fe4212916ae58.jpeg

 3d9d0795645820512853cdaea90872c6.jpeg

Ducter Ohmmeter


The Ducter Ohmmeter, an electromechanical instrument, measures low resistances. It includes a permanent magnet, similar to a PMMC instrument, and two coils positioned within the magnetic field and at right angles to each other, rotating freely about a common axis. The diagram below illustrates a Ducter Ohmmeter and the necessary connections to measure an unknown resistance R.


One of the coil called current coil, is connected to current terminals C 1 and C2,while the other coil called, voltage coil is connected to potential terminals V1 and V2. Voltage coil carries current proportional of the voltage drop across R and so is its torque produced. Current coil carries current proportional to the current flowing through R and so is its torque too. Both the torque acts in opposite direction and the indicator come to halt when the two are equal. This instrument is useful for resistance in range 100µΩ to 5Ω.


0d12e6044a2ed66992e502048d6d43d1.jpeg


Measurement of Medium Resistance (1Ω – 100kΩ)


Ammeter Voltmeter Method


This is the most crude and simplest method of measuring resistance. It uses one ammeter to measure current, I and one voltmeter to measure voltage, V and we get the value of resistance as

 

Now we can have two possible connections of ammeter and voltmeter, shown in the figure below.Now in figure 1, the voltmeter measures voltage drop across ammeter and the unknown resistance, hence


Hence, the relative error will be,


For connection in figure 2, the ammeter measures the sum of current through voltmeter and resistance, hence


The relative error will be,


It can be observed that the relative error is zero for R a = 0 in first case and Rv = ∞ in second case. Now the questions stand that which connection to be used in which case. To find out this we equate both the errors


Hence for resistances greater than that given by above equation we use the first method and for less than that we use second method.


7a61bcb10fd19201cca1dcfc06ba5aff.jpeg04291f4354ab5acb262fb8608c16823c.jpeg

5bdb3700ff95809436d1122f667a9254.jpeg


Wheatstone Bridge Method


This is the simplest and the most basic bridge circuit used in measurement studies. It mainly consists of four arms of resistance P, Q; R and S. R is the unknown resistance under experiment, while S is a standard resistance. P and Q are known as the ratio arms. An EMF source is connected between points a and b while a galvanometer is connected between points c and d.


A bridge circuit always works on the principle of null detection, i.e. we vary a parameter until the detector shows zero and then use a mathematical relation to determine the unknown in terms of varying parameter and other constants. Here also the standard resistance, S is varied in order to obtain null deflection in the galvanometer. This null deflection implies no current from point c to d, which implies that potential of point c and d is same. Hence


Combining the above two equations we get the famous equation –


4eb241e9ffb29bbec44e2a530b7dadaf.jpeg

d69309c9bd554c6de818fa312aee0c85.jpeg


Substitution Method


The figure below shows the circuit diagram for resistance measurement of an unknown resistance R. S is a standard variable resistance and r is a regulating resistance.


First the switch is place at position 1 and the ammeter is made to read a certain amount of current by varying r. The value of ammeter reading is noted. Now the switch is moved to position 2 and S is varied in order to achieve the same ammeter reading as it read in the initial case. The value of S for which ammeter reads same as in position 1, is the value of unknown resistance R, provided the EMF source has constant value throughout the experiment.


23113929cb6eb14abb715920f09bf463.jpeg


Measurement of High Resistance (>100kΩ)


Loss of Charge Method


In this method we utilize the equation of voltage across a discharging capacitor to find the value of unknown resistance R. Figure below shows the circuit diagram and the equations involved are-


However the above case assumes no leakage resistance of the capacitor. Hence to account for it we use the circuit shown in the figure below. R 1


03abfaa13d8a37415ef315d29dba7b22.jpeg


We follow the same procedure but first with switch S1 closed and next with switch S1 open. For the first case we get


For second case with switch open we get


Using R 1 from above equation in equation for R’ we can find R.


afe6f1f75eba7546b86755ceb31acae2.jpeg


Megohm Bridge Method


In this method we use the famous Wheatstone bridge philosophy but in a slightly modified way. A high resistance is represented as in the figure below.


G is the guard terminal. Now we can also represent the resistor as shown in the adjoining figure, where R AG and RBG are the leakage resistances. The circuit for measurement is shown in the figure below.


1b340dd10606b6180c442459e7c6dc3f.jpeg


It can be observed that we actually obtain the resistance which is parallel combination of R and R AG. Although this causes very insignificant error.


6966c3185dfbf64bac70f9dceabb1c5a.jpeg

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.