Weston Type Frequency Meter

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Weston Frequency Meter Definition


The Weston frequency meter measures frequency by using the deflection of a magnetic needle caused by perpendicular currents in two coils.


Construction


It includes two coils, three inductors, and two resistors arranged in a specific configuration.

 

Circuit Diagram


The diagram shows Coil 1 with a series resistor (R1) and reactance coil (L1), and Coil 2 with a series reactance coil (L2) and parallel resistor (R2).


f61b5b19529ea3da3a85f47797a12a54.jpeg


Working Principle


Axis of both coils are marked as shown. Scale of the meter is calibrated such that at standard frequency the pointer will take position at 45o. Coil 1 contains a series resistor marked R1 and reactance coil marked as L1, while the coil 2 has a series reactance coil marked as L2 and parallel resistor marked as R2. The indcuctor which is marked as L0 is connected in series with the supply voltage in order to reduce the higher harmonic means here this inductor is working as a filter circuit. Let us look at the working of this meter.


When we apply voltage at the standard frequency, the pointer stays at the normal position. If the frequency increases, the pointer moves to the left, indicating a higher frequency. If the frequency decreases, the pointer moves to the right, indicating a lower frequency. If the frequency drops below normal, the pointer crosses the normal position and moves further left.


Let’s examine the internal working of this meter. The voltage drop across an inductor is proportional to the frequency of the source voltage. As the frequency of the applied voltage increases, the voltage drop across inductor L1 increases, which raises the current across Coil 1. This causes the current through Coil 1 to increase and the current through Coil 2 to decrease.


As the current through Coil 1 increases, its magnetic field also increases, causing the magnetic needle to move more to the left, indicating higher frequency. If the frequency decreases, a similar action occurs, but the pointer moves to the right.


Behavior with Frequency Changes


The needle moves left with higher frequencies and right with lower frequencies, reflecting the change in the current through the coils.

 

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.