What are the Power Factor Meters?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

What are the Power Factor Meters?


Power factor meter definition


Power factor meters are devices used to accurately measure the power factor in AC circuits and are essential for industrial applications.


Type of electric dynamometer


This type of meter measures the power factor by using two coils (a resistance coil and an inductor coil) to determine the phase difference between voltage and current.


1bfdb883a95cedabbd4c2c7b271a2384.jpeg


Now the pressure coil is divided into two parts, one part is pure induction, the other part is pure resistance, as shown by the resistor and the inductor. At present, the reference plane forms an Angle A with coil 1. The Angle between coils 1 and 2 is both 90o. 


Therefore, coil 2 is forming an Angle (90o+ A) to replace the reference plane. The scale of the instrument has been correctly calibrated, as shown in the figure, for the cosine value of Angle A. Let's label the resistance connected to coil 1 as R and the inductor connected to coil 2 as L. Now, during the power factor measurement, adjust the values of R and L so that R = wL so that the two coils carry equal amounts of current. Therefore, the current lag 90o through coil 2 is referenced by the current in coil 1 because the coil 2 path is highly inductive in nature.


To understand the deflection torque in this power factor meter, we recognize that there are two deflection torques: one on coil 1 and the other on coil 2. The coil windings are arranged so that these torques are reversed, balancing the Pointers when they are equal. The mathematical expression of the deflection torque of coil 1 is:


aefa732abb5da4b5e6a5774a77180417.jpeg


b7776195309c3f3a500e563317407e4d.jpeg


Working principle


The working principle of the instrument is to balance the deflection torque of the coil, and the deflection Angle indicates the phase Angle.


Advantage


  • Because the use of iron components is minimal and the loss is small, the error in the small frequency range is also small compared to the moving iron type instrument.


  • Their high torque is the weight ratio.


Shortcoming


  • Less working force than moving iron instruments.



  • The scale does not extend beyond 360o.



  • The calibration of electric dynamometer type instrument is greatly affected by the variation of voltage frequency of power supply.



  • They are very expensive compared to other tools.


Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.