What is an Ohmmeter?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is an Ohmmeter?


Ohmmeter Definition


An ohmmeter is defined as a device that measures electrical resistance, indicating how much a material opposes electric current.


Ohmmeters types  


Series Type Ohmmeter


172f6a6cffd530944d01708c580f8982.jpeg


The ohmmeter connects a battery, a series adjustable resistor, and a meter for readings. The resistance to be measured is connected at terminal OB. When the circuit is completed, current flows, and the meter shows the deflection.


When the resistance to be measured is very high then the current in the circuit will be very small and the reading of that instrument is assumed to be the maximum resistance to be measured.When resistance to be measured is zero then the instrument reading is set to zero position which gives zero resistance.


D’Arsonval Movement


D’Arsonval movement is used in DC measuring instruments. When a current-carrying coil is placed in a magnetic field, it experiences a force. This force moves the meter’s pointer, providing the reading.

 

0f41088fa740341005be5471e962d57d.jpeg

 

91f10654df27bf51c8fe186fad8c36d1.jpeg

 

This type of instrument consists of a permanent magnet and a coil that carries current and is placed in between them. The coil may be of rectangular or circular in shape. The iron core is used to provide a flux of low reluctance so it produces a high-intensity magnetic field.


Due to high-intensity magnetic fields, the deflecting torque produced is of large value due to which sensitivity of the meter is also increased. The current which entered comes out of two control springs, one in the upper side and one in the lower side.


If the direction of current is reversed in these types of instruments, then torque direction will also be reversed so these types of instruments are applicable in DC measurements only. The deflecting torque is directly proportional to the deflection angle hence these types of instruments have a linear scale.


To limit the deflection of the pointer we have to use damping which provides an equal and opposite force to the deflecting torque and hence the pointer comes to rest at a certain value.The indication of the breeding is given by a mirror in which a beam of light is reflected on to the scale and hence deflection can be measured.


There are many advantages due to which we use the D’Arsonval type instrument. They are-

 


  • They have a uniform scale.

  • Effective eddy current damping.

  • Low power consumption.

  • No hysteresis loss.

  • They are not affected by stray fields.

 


Owing to posses those major advantages we can use this type of instrument. However, they suffer from drawbacks such as:

 


  • It cannot be used in alternating current systems (DC current only)



  • Costlier compared to MI instruments.



  • There may be an error due to the aging of springs by which we may not get accurate results.


However in the case of resistance measurement, we go for DC measurement because of the advantages offered by PMMC instruments and we multiply that resistance by 1.6 to find out AC resistance, so these instruments are much widely used due to their advantages. The disadvantages offered by it are dominated by the advantages so they are used.


Series type Ohmmeter


f8740b9c1c553a4d94f826ad436a5ab6.jpeg


The series type ohmmeter consists of a current limiting resistor R1, Zero adjusting resistor R2, EMF source E, Internal resistance of D’Arsonval movement Rm and the resistance to be measured R.When there is no resistance to be measured, the current drawn by the circuit will be maximum and the meter will show a deflection.


By adjusting R2 the meter is adjusted to a full-scale current value since the resistance will be zero at that time. The co-responding pointer indication is marked as zero. Again when the terminal AB is opened it provides very high resistance and hence almost zero current will flow through the circuit. In that case, the pointer deflection is zero which is marked at a very high value for resistance measurement.


So a resistance between zeros to a very high value is marked and hence can be measured. So, when resistance is to be measured, the current value will be somewhat less than the maximum and the deflection is recorded and accordingly, resistance is measured.


This method is good but it posses certain limitations such as the decrease in the potential of the battery with its use so adjustment must be made for every use. The meter may not read zero when terminals are shorted, these types of problems may arise which is counteracted by the adjustable resistance connected in series with the battery.


Shunt Type Ohmmeter


0d02a3f8ce469ac73689016c52aa1ee3.jpeg


In this type of meters, we have a battery source and an adjustable resistor is connected in series with the source. We have connected the meter in parallel to the resistance which is to be measured. There is a switch by the use of which we can on or off the circuit.


The switch is opened when it is not in use. When the resistance to be measured is zero, the terminals A and F are shorted so the current through the meter will be zero. The zero position of the meter denotes the resistance to be zero.


When the resistance connected is very high, then a small current will flow the terminal AF and hence full-scale current is allowed to flow through the meter by adjusting the series resistance connected with the battery.


So, full-scale deflection measures very high resistance. When the resistance to be measured is connected between A and F, The pointer shows a deflection by which we can measure the resistance values.


In this case, the battery problem may arise which can be counteracted by adjusting the resistance. The meter may have some error due to its repeated use also.


Multi-Range Ohmmeter

 

6bb33e0bc16a5ecea7701a8115cff8f5.jpeg


This instrument provides the reading up to a very wide range. In this case, we have to select the range switch according to our requirements. An adjuster is provided so that we can adjust the initial reading to be zero.


The resistance to be measured is connected in parallel to the meter. The meter is adjusted so that it shows full-scale deflection when the terminals in which the resistance connected is full-scale range through the range switch.


When the resistance is zero or short circuit, there is no current flow through the meter and hence no deflection. Suppose we have to measure a resistance under 1 ohm, then the range switch is selected at the 1-ohm range at first.


Then that resistance is connected in parallel and the corresponding meter deflection is noted. For 1 ohm resistance, it shows full-scale deflection but for the resistance other than 1 ohm it shows a deflection which is less than the full load value, and hence resistance can be measured.


This is the most suitable method of all the ohmmeters as we can get an accurate reading in this type of meter. So this meter is most widely used nowadays.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.