What is LVDT?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is LVDT?


Definition of LVDT


The LVDT, or Linear Variable Differential Transformer, is an inductive transducer that converts linear motion into an electrical signal. It is highly valued for its precision and reliability.The output across secondary of this transformer is the differential thus it is called so. It is very accurate inductive transducer as compared to other inductive transducers.

 

4e79998ec09fa00837c109bd1623dd9a.jpeg

 

Construction of LVDT


Main Features of Construction

 

  • The transformer consists of a primary winding P and two secondary windings S1 and S2 wound on a cylindrical former (which is hollow in nature and contains the core).



  • Both the secondary windings have an equal number of turns, and we place them on either side of primary winding



  • The primary winding is connected to an AC source which produces a flux in the air gap and voltages are induced in secondary windings.



  • A movable soft iron core is placed inside the former and displacement to be measured is connected to the iron core.



  • The iron core is generally of high permeability which helps in reducing harmonics and high sensitivity of LVDT.



  • The LVDT is placed inside a stainless steel housing because it will provide electrostatic and electromagnetic shielding.



  • The both the secondary windings are connected in such a way that resulted output is the difference between the voltages of two windings.


 

f6ff8a6e96c31a713a8f433bece53641.jpeg



Principle of Operation and Working


As the primary is connected to an AC source so alternating current and voltages are produced in the secondary of the LVDT. The output in secondary S1 is e1 and in the secondary S2 is e2. So the differential output is,

 

c3427ff675840a769de1d3b967c9e128.jpeg

 

This equation explains the principle of Operation of LVDT.

 

Now three cases arise according to the locations of core which explains the working of LVDT are discussed below as,

 

175b64eb469c73fbe31c90d2f4ecb44c.jpeg

 

  • CASE I When the core is at null position (for no displacement).When the core is at null position then the flux linking with both the secondary windings is equal so the induced emf is equal in both the windings. So for no displacement the value of output eout is zero as e1 and e2 both are equal. So it shows that no displacement took place.



  • CASE II When the core is moved to upward of null position (For displacement to the upward of reference point)



  • In the this case the flux linking with secondary winding S1 is more as compared to flux linking with S2. Due to this e1 will be more as that of e2. Due to this output voltage eout is positive.



  • CASE III When the core is moved to downward of Null position (for displacement to the downward of the reference point). In this case magnitude of e2 will be more as that of e1. Due to this output eout will be negative and shows the output to downward of the reference point.


Output VS Core Displacement


The output voltage of an LVDT displays a linear relationship with the core’s displacement, as represented by a linear curve on a graph.Some important points about magnitude and sign of voltage induced in LVDT

 

39a889a0dc0ea31c673f5fae9695e825.jpeg

 

The amount of change in voltage either negative or positive is proportional to the amount of movement of core and indicates amount of linear motion.By noting the output voltage increasing or decreasing the direction of motion can be determinedThe output voltage of an LVDT is linear function of core displacement .


Advantages of LVDT


  • High Range – LVDTs can measure a wide range of displacements, from as little as 1.25 mm up to 250 mm, which enhances their versatility in various applications.



  • No Frictional Losses – As the core moves inside a hollow former so there is no loss of displacement input as frictional loss so it makes LVDT as very accurate device.



  • High Input and High Sensitivity – The output of LVDT is so high that it doesn’t need any amplification. The transducer posseses a high sensitivity which is typically about 40V/mm.



  • Low Hysteresis – LVDTs show a low hysteresis and hence repeatability is excellent under all conditions



  • Low Power Consumption – The power is about 1W which is very as compared to other transducers.



  • Direct Conversion to Electrical Signals – They convert the linear displacement to electrical voltage which are easy to process


Disadvantages of LVDT


  • Due to their sensitivity to stray magnetic fields, LVDTs require protective setups to ensure accurate performance and prevent interference.



  • LVDT gets affected by vibrations and temperature.



  • It is concluded that they are advantageous as compared than any other inductive transducer.


Applications of LVDT


  • We use LVDT in the applications where displacements to be measured are ranging from a fraction of mm to few cms. The LVDT acting as a primary transducer converts the displacement to electrical signal directly.



  • The LVDT can also act as a secondary transducer. E.g. the Bourbon tube which acts as a primary transducer and it converts pressure into linear displacement and then LVDT coverts this displacement into an electrical signal which after calibration gives the readings of the pressure of fluid.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.