What is an Watt Hour Meter?


Watt-Hour Meter Definition


A watt-hour meter is defined as a device that measures and records the electrical power passing through a circuit over a period of time.


Tampering and Security


A common tampering method involves attaching a magnet to the outside of old energy meters. Using capacitance and inductive loads can also reduce the rotor speed.


The most modern meter can store up the previous value with time and date. So the tampering is avoided. Utilities install remote reporting meters to detect tampering.


Types of Watt Hour Meter


Electromechanical Type Induction Meter


A non-magnetic and electrically conductive aluminum metal disc is made to revolve in a magnetic field in this type of meter. The rotation is made possible with the power passing through it. The rotation speed is proportional to the power flow through the meter.


Gear trains and counter mechanisms are incorporated to integrate this power. This meter works by counting the total number of revolutions, and it is relative to the usage of energy.


A series magnet is connected in series with the line, which comprises a coil of few turns with thick wire. A shunt magnet is connected in shunt with the supply and comprises a large number of turns with thin wire.


A braking magnet, a permanent magnet, is included for stopping the disc at the time of power failure and placing the disc in position. This is done by applying a force opposite to the rotation of the disc.


A flux is produced by the series magnet that is directly proportional to the current flow, and the shunt magnet corresponding produces another flux to the voltage. Because of the inductive nature, these two fluxes lag each other by 90o.


b3fdb211ea3480341bb9eb4342ebd38f.jpeg


An eddy current is developed in the disc, which is the interface of the two fields. A force corresponding produces this current to the product of instantaneous current, voltage, and phase angle.


A break torque is developed on the disc by the braking magnet positioned over one side of the disc. The speed of the disc becomes constant when the following condition is achieved, Braking torque = Driving torque.


The gear arrangement linked with the shaft of the disc is implemented for recording the number of revolutions. This is for single-phase AC measurement. An additional number of coils can be implemented for different phase configurations.


d727978e65c8f801d6cddde2a077a44a.jpeg


Electronic Energy Meter


The major feature of the electronic meter other than power usage measurement is that it can display the energy usage on a LED or LCD. In some advanced meters, the readings can be transmitted to remote areas.


It can also record the amount of usable energy in on-peak hours and off-peak hours. In addition, this meter can record the parameters of supply and load like voltages, reactive power used, the instantaneous rate of usage demand, power factor, maximum demand, etc.


Smart Energy Meter


In this type of meter, communication in both directions (Utility to the customer and customer to the utility) is possible.


Customer to utility communication includes parameter values, consumption of energy, alarms, etc. The utility to consumer communication includes disconnect/reconnect instructions, automatic meter reading system, upgrading of the software of the meter, etc.


Modems are implemented in this meter to make communications easy. The communication system includes fiber cable, power line communication, wireless, telephone, etc.


Advantages of Different Types of Watt Hour Meter


1d9b2c52bdfd5eca9e3cb99869b5dd58.jpeg

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.