What is a First Order Control System?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is a First Order Control System?


First Order Control System Definition


A first order control system uses a simple type of differential equation to relate inputs and outputs, focusing on the first derivative of time only.

 

4616c6a0ccfd0246e468d25c1b64388c.jpeg

 

The transfer function (input-output relationship) for this control system is defined as:

 

9660c72a9648773ea0a57b33d2f729eb.jpeg

 

  • K is the DC Gain (DC gain of the system ratio between the input signal and the steady-state value of output)


  • T is the time constant of the system (the time constant is a measure of how quickly a first-order system responds to a unit step input).


First Order Control System Transfer Function


A transfer function represents the relationship between the output signal of a control system and the input signal, for all possible input values.


Poles of a Transfer Function


The poles of the transfer function are the value of Laplace Transform variable(s), which cause the transfer function to become infinite.The denominator of a transfer function is actually the poles of function.


Zeros of a Transfer Function


The zeros of the transfer function are the values of the Laplace Transform variable(s), that causes the transfer function becomes zero.The nominator of a transfer function is actually the zeros of the function.


First Order Control System


Here we discuss the first-order control system without zeros. The first-order control system tells us the speed of the response that what duration it reaches the steady-state.If the input is a unit step, R(s) = 1/s so the output is a step response C(s). The general equation of 1st order control system is , i.e is the transfer function.

 

026b61ba6d622e5653f1e5c94cc2e207.jpeg

 

There are two poles, one is the input pole at the origin s = 0 and the other is the system pole at s = -a, this pole is at the negative axis of the pole plot.Using MATLAB’s pzmap command, we can identify the poles and zeros of the system, crucial for analyzing its behavior.We now taking the inverse transform so total response become which is the sum of forced response and natural response.

 

7b44e6d264096673d40e3476b96b49a9.jpeg


Due to the input pole at the origin, produces the forced response as name describe by itself that giving forced to the system so it produces some response which is forced response and the system pole at -a produces a natural response which is due to the transient response of the system.


After some calculation, here General form of the first-order system is C(s) = 1-e-at that is equal to forced response which is “1” and natural response which is equal to “e-at”. The only thing which is needed to find is the parameter “a”.


Many techniques like a differential equation or inverse Laplace Transform, these all solve the total response but these are time-consuming and laborious.


The use of poles, zeros, and there some fundamental concept gives us the qualitative information to solve the problems and due to these concepts, we can easily tell the speed of response and the time of a system to reach the steady-state point.


Let us describe the three transient response performance specifications, the time constant, rise time, and settling time for a first-order control system.


Time Constant of a First Order Control System


The time constant can be defined as the time it takes for the step response to rise up to 63% or 0.63 of its final value. We refer to this as t = 1/a. If we take reciprocal of time constant, its unit is 1/seconds or frequency.


We call the parameter “a” the exponential frequency. Because the derivative of e-at is -a at t = 0. So the time constant is considered as a transient response specification for a first-order control system.


We can control the speed of response by setting the poles. Because the farther the pole from the imaginary axis, the faster the transient response is. So, we can set poles farther from the imaginary axis to speed up the whole process.


Rise Time of a First Order Control System


The rise time is defined as the time for the waveform to go from 0.1 to 0.9 or 10% to 90% of its final value. For the equation of rising time, we put 0.1 and 0.9 in the general first-order system equation respectively.


For t = 0.1

 

For t = 0.9

 


Taking the difference between 0.9 and 0.1


Here the equation of rising time. If we know the parameter of a, we can easily find the rise time of any given system by putting “a” in the equation.

 

8125b82726fa75671aac319f71c62846.jpeg


Settling Time of a First Order Control System


The settling time is defined as the time for the response to reach and stay within 2% of its final value. We can limit the percentage up to 5% of its final value. Both percentages are a consideration.

 

The equation of settling time is given by Ts = 4/a.


 

By using these three transient response specifications, we can easily compute the step response of a given system that’s why this qualitative technique is useful for order systems equations.

 


Conclusion of First Order Control Systems


After learning all things related to 1st order control system, we come to the following conclusions:

 


  • A pole of the input function generates the form of the forced response. It is because of the pole at the origin which generates a step function at the output.



  • A pole of the transfer function generates a natural response. It the pole of the system.



  • A pole on the real axis generates an exponential frequency of the form e-at. Thus, the farther the pole to the origin, the faster the exponential transient response will decay to zero.



  • Understanding poles and zeros allows us to enhance system performance and achieve faster, more accurate outputs. 

 


Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
How Does Power Dispatching Ensure Grid Stability and Efficiency?
How Does Power Dispatching Ensure Grid Stability and Efficiency?
Electric Power Dispatching in Modern Power SystemsThe power system is a critical infrastructure of modern society, providing essential electrical energy for industrial, commercial, and residential use. As the core of power system operation and management, electric power dispatching aims to meet electricity demand while ensuring grid stability and economic efficiency.1. Basic Principles of Electric Power DispatchingThe fundamental principle of power dispatching is to balance supply and demand by
Echo
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.