What are Flexible AC Transmission Systems ?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What are Flexible AC Transmission Systems ?


FACTS Definition


Flexible AC Transmission Systems (FACTS) are defined as systems that use power electronics to improve the control and power transfer in AC transmission networks.

 


  • Features of FACTS

  • Fast voltage regulation

  • Increased power transfer over long AC lines

  • Damping of active power oscillations

  • Load flow control in meshed systems

 


Thereby significantly improving the stability and performance of existing and future transmission systems.With Flexible AC Transmission Systems (FACTS), power companies can better utilize existing networks, increase the availability and reliability of their lines, and improve dynamic and transient network stability, ensuring a better quality of supply.

 


Influence of Reactive Power Flow on Power System Voltage

 


b25a7ef223cdeecdd67ce3cb96b11cd1.jpeg

 


Reactive Power Compensation


Consumer loads need reactive power that varies continuously, increasing transmission losses and affecting voltage in the network. To prevent high voltage fluctuations or power failures, this reactive power must be balanced. Passive components like reactors or capacitors can supply inductive or capacitive reactive power. Fast and precise reactive power compensation, using thyristor-switched and thyristor-controlled components, can improve transmission efficiency and control, replacing slower mechanical switches.

 


Effects of Reactive Power Flow


Reactive power flow has the following effects:


 

  • Increase in transmission system losses



  • Adding to power plant installations



  • Adding to operating costs



  • Major influence on system voltage deviation



  • Degradation of load performance at under voltage



  • Risk of insulation breakdown at over-voltage



  • Limitation of power transfer


  • Steady-state and dynamic stability limits

 


Parallel and Series

 


aed847231042af269247c3cd8b1b4ad5.jpeg

 


Fig. Shows today’s most common shunt compensation devices, their influence on the most important transmission parameters, and typical applications.

 


Fig.: The active power/ transmission angle equation illustrates which FACTS components selectively influence which transmission parameters.

 


51282d3e9bc68605097e95052dafa0e2.jpeg

 


Protection and Control Systems


To improve redundancy management, special modules were developed to supplement the SIMATIC TDC automation system. These modules issue triggering signals to thyristor valves and take up less space than previous technology. 


SIMATIC TDC’s flexible interface design allows it to replace existing systems easily. This integration can be done with minimal delay, ensuring measured values from old systems are processed by the new control system. The space efficiency of SIMATIC TDC also allows parallel configuration with existing systems.

 


Human Machine Interface.The interface between the operator and the plant .(HMI = Human Machine Interface) is the standardized.SIMATIC Win CC visualization system, which further simplifies operation and facilitates the adaptation of graphical user interfaces to the operator’s requirements.

 

f6ad5d66b5466abc8c361f2884fcc0d5.jpeg 

Hardware for Control and Protection


Siemens offers the latest in control and protection for FACTS – the tried and tested SIMATIC TDC (Technology and Drive Control) automation system. SIMATIC TDC is used worldwide in almost every industry and has been proven in both production and process engineering as well as in many HVDC and FACTS applications. 


Operating personnel and project planning engineers work exclusively with a standardized, universal hardware and software platform, enabling them to perform demanding tasks more rapidly. One of the main considerations in developing this automation system was to ensure the highest degree of availability of the FACTS – which is why all control and protection systems, as well as the communication links, are configured redundantly (if requested by the customer).

 


The new instrumentation and control technology also permits the use of a high-performance fault recorder operating at a 25 kHz sampling rate. New instrumentation and control technology reduces the period between fault recording and the printout of the fault report from several minutes (previously) to 10 seconds (now).

 


Converter for FACTS


LTT – Light Triggered Thyristors


Thyristors control passive components in reactive power compensation systems. Siemens’ direct light triggering system activates thyristors with a 10-microsecond light pulse at 40 milliwatts. This device includes overvoltage protection, making it self-protecting if forward voltage exceeds limits.


 The light pulse travels through fiber optics from the valve control to the thyristor gate. Conventional systems use electrically triggered thyristors, requiring pulses of several watts generated by nearby electronic equipment. Direct light triggering reduces electrical components in the thyristor valve by 80%, improving reliability and electromagnetic compatibility. Additionally, the new thyristor technology ensures long-term availability of electronic components for at least 30 years.

 


Thyristor valves from Siemens are assembled from 4-inch or 5-inch thyristors, depending on the current- carrying capacity/rated current required. Thyristor technology has been under constant development since the early 1960s. At present, thyristors can safely and economically handle blocking voltages of up to 8-kilovolts and rated currents of up to 4,200 amperes.

 

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
How Does Power Dispatching Ensure Grid Stability and Efficiency?
How Does Power Dispatching Ensure Grid Stability and Efficiency?
Electric Power Dispatching in Modern Power SystemsThe power system is a critical infrastructure of modern society, providing essential electrical energy for industrial, commercial, and residential use. As the core of power system operation and management, electric power dispatching aims to meet electricity demand while ensuring grid stability and economic efficiency.1. Basic Principles of Electric Power DispatchingThe fundamental principle of power dispatching is to balance supply and demand by
Echo
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.