Foundation Design Definition


The foundation design for transmission towers involves creating stable bases using RCC, designed to withstand various loads and soil conditions.

 


Different Soil Types


Transmission tower foundations must adapt to different soil types like black cotton soil, fissured rock, and sandy soil, each requiring unique construction methods.

 


Dry Fissured Rock


Foundations in dry fissured rock need special considerations like undercuts and anchor bars for stability.

 


Stability Factors


Ensuring stability against sliding, overturning, and buoyancy is crucial, with specific safety factors for normal and short circuit conditions.

 


Protective Measures


Additional protection for foundations is necessary in aggressive soils to prevent damage and ensure longevity.

 


Design of Foundation of Transmission Towers in Different Soils

 


  • All foundation shall be of RCC. The design and construction of RCC structures shall be carried out as per IS:456 and minimum grade of concrete shall be M-20.



  • Limit state method of design shall be adopted.



  • Cold twisted deformed bars as per IS:1786 or TMT bars shall be used as reinforcement.



  • Foundations shall be designed for the critical loading combination of the steel structure and or equipment and/or superstructure.



  • Protection should be provided to foundations when needed, especially for aggressive soils like alkaline soil, black cotton soil, or any soil harmful to concrete foundations.



  • All structures must be checked for stability against sliding and overturning during construction and operation under various load combinations.



  • When checking for overturning, consider the weight of the soil above the footing, but do not include the inverted frustum of the earth on the foundation.



  • Base slab of any underground enclosure shall also be designed for maximum ground water table. Minimum factor of safety of 1.5 against bouncy shall be ensured.


  • Tower and equipment foundations must have a safety factor of 2.2 for normal conditions and 1.65 for short circuit conditions to prevent sliding, overturning, and pullout.

 

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis