What is the Working Principle of Alternator?

Encyclopedia
08/19/2024


What is the Working Principle of Alternator?


Alternator definition


An alternator is a machine that uses electromagnetic induction to convert mechanical energy into alternating current electricity.


Working principle


The alternator works on the basis of Faraday's Law, in which motion between a conductor and a magnetic field induces an electric current.


Induction process


Suppose that this one-turn cycle ABCD can be rotated against axes a-b. Let's say the cycle starts spinning clockwise. Post-90 o rotation: One side of the loop AB or conductor AB is located in front of the S pole and conductor CD is located in front of the N pole. At this position, the tangential motion of conductor AB is just perpendicular to the flux line from the N to the S poles. Therefore, the flux cutting rate of conductor AB is the largest here, and for this flux cutting, conductor AB will generate an induced current, the direction of which can be determined by Fleming's right hand rule. According to this rule, the direction of this current will be from A to B. At the same time, the conductor CD is located below the N pole, and here also if we apply Fleming's right hand rule, we will find the direction of the induced current, which will go from C to D.


After a further clockwise rotation of 90 degrees, the ring ABCD reaches a vertical position. Here, the motion of the conductors AB and CD are aligned parallel to the flux lines, so the magnetic flux is not cut and therefore no current is generated.


73c7092ac665732c115dd317021a5164.jpeg



Alternating current



After another 90 turns clockwise, o turns again to the horizontal position, where conductor AB is under pole N and CD is under pole S. Here if we apply Fleming's right hand rule again, we will see that the induced current in conductor AB is from point B to A, and the induced current in conductor CD is from D to C.


As the loop moves from vertical to horizontal, the current in the conductor increases from zero to a maximum. Current flows from B to A, A to D, D to C, C to B, from A to B, B to C, C to D, and D to A in a closed loop. When the loop again approaches the vertical position, the current drops to zero. As it continues to rotate, the current changes direction. Each full turn causes the current to peak, drop to zero, peak in the opposite direction, and then return to zero, completing one sine wave cycle per 360 degrees of rotation. The process illustrates how alternating current can be generated by rotating a conductor in a magnetic field.


0da84797e54cd0971f8b799121348f31.jpeg

Practical configuration


Modern alternators typically have fixed armatures and rotating magnetic fields that increase the efficiency of generating three-phase alternating current for a wide range of power distribution.

7e000d57e2600a9bdbd63578a7348ad9.jpeg

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!