Why is an induction motor called a rotating transfer motor?

Encyclopedia
10/04/2024

An induction motor is called a "rotating transformer" due to its fundamental operating principle, which closely resembles that of a conventional transformer. Both induction motors and transformers rely on electromagnetic induction to transfer energy between their components, but they differ in the physical arrangement and application.


  • Principle of Operation: In an induction motor, the stator windings create a rotating magnetic field. This field, when it interacts with the rotor windings, induces an electromotive force (EMF) in the rotor, causing it to rotate.


  • Similarity to Transformers: The key similarity between an induction motor and a transformer lies in the fact that both devices use magnetic fields to transfer energy without direct electrical contact between the primary and secondary components. In a transformer, the primary winding is energized by an AC supply, creating a magnetic field that induces a voltage in the secondary winding, also through electromagnetic induction.



  • Rotating Magnetic Field and Energy Transfer: The rotating magnetic field in an induction motor is analogous to the stationary magnetic field in a transformer. The energy transfer in both cases occurs through the interaction of magnetic fields, with the main difference being that the transformer transfers energy between stationary parts, while the induction motor transfers energy to a rotating part (the rotor).



  • Summary: In summary, an induction motor is called a "rotating transformer" because its operation involves the induction of EMF in a rotor due to a rotating magnetic field, much like how a transformer transfers energy through the interaction of magnetic fields without direct electrical connection between primary and secondary components.



This shared principle of electromagnetic induction is what gives the induction motor its distinctive name within the realm of electrical engineering.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025