What is the advisable minimum frequency for a 50Hz motor (SEW)?

Encyclopedia
10/05/2024

For 50Hz motors, especially brand motors like SEW, there is a recommended minimum operating Frequency when using a Variable Frequency Drive (VFD) for speed control. According to the information you provided, the ordinary motor under the control of the inverter, can not be lower than 20Hz, below 20Hz will lose control. This means that, in most cases, when a 50Hz motor is operated under the control of a frequency converter, the minimum frequency should not be lower than 20Hz.


Minimum frequency considerations


  • Motor design: The design of the motor is usually 50Hz as the reference frequency, when the frequency is reduced, the performance of the motor (such as torque, power) will also be affected.


  • Control performance: Frequency below a certain threshold may cause the control of the motor to become unstable, for example, the speed of the motor may become difficult to control.


  • Heat dissipation problems: When the frequency is reduced, the speed of the motor is also reduced, which may lead to heat dissipation problems because the cooling efficiency of the fan will be reduced.


  • Mechanical resonance: Reducing the frequency may cause the motor to operate near the mechanical resonance frequency, which may cause the motor to shake more and affect its service life.


  • Electromagnetic interference: When operating at low frequencies, the motor may produce more electromagnetic interference (EMI), which may have an impact on surrounding electronic equipment.



SEW motor special case


SEW motor as an industrial grade motor, its design is usually able to adapt to a certain frequency range. However, even a high-quality motor such as SEW has its minimum frequency limit. If you need to run the motor at a frequency below 50Hz, it is usually recommended not to run below 20Hz. This is to ensure the stable operation of the motor and extend the service life of the motor.


Precautions when using frequency converter


When using a frequency converter to control the speed of the motor, the following points should be noted:


  • Frequency regulation: The frequency should be gradually adjusted to avoid mutations to prevent the motor and load from being impacted.


  • Load matching: Ensure that the capacity of the inverter matches the motor to avoid overload or underload.


  • Protection Settings: Correctly set the protection function of the inverter, such as over current, over voltage, under voltage protection.


  • Maintenance: Regularly check the status of the motor and inverter, timely maintenance.



Sum up


For SEW motors at 50Hz, the recommended minimum frequency should generally not be less than 20Hz. This is mainly to ensure the stable operation of the motor, prevent control instability, avoid heat dissipation problems, reduce mechanical resonance and reduce electromagnetic interference. In practical applications, the appropriate operating frequency should be selected according to the specific working conditions and the recommendations of the motor manufacturer. If you need to operate at lower frequencies, you should consult a professional motor supplier or technician to ensure that the motor can work safely and reliably.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec