What is the effect of slip on torque in an AC induction motor?

Encyclopedia
11/04/2024

Slip (Slip) is an important parameter for AC induction motors, and it significantly affects the motor's torque (Torque). Slip is defined as the ratio of the difference between the synchronous speed and the actual rotor speed to the synchronous speed. Slip can be expressed using the following formula:

5ef118a3ade0349beb74b999dd0bd002.jpeg

where:

s is the slip

ns is the synchronous speed

nr is the actual rotor speed

Impact of Slip on Torque

Slip at Startup

At startup, the rotor is stationary, i.e., 

nr=0, so the slip s=1.

At startup, the rotor current is maximum, and the magnetic flux density is also maximum, resulting in a high starting torque (Starting Torque).

Slip During Operation:

When the motor is running, the rotor speed 

nr is close to but less than the synchronous speed 

ns , so the slip 

s is less than 1 but greater than 0.

The larger the slip, the greater the rotor current, and consequently, the greater the electromagnetic torque. Therefore, slip is directly proportional to torque.

Maximum Torque

There is a specific slip value, known as the critical slip (Critical Slip), at which the motor produces maximum torque (Maximum Torque).

Maximum torque typically occurs at a slip of about 0.2 to 0.3, depending on the motor's design parameters, such as rotor resistance and leakage reactance.

Steady-State Operation

During steady-state operation, the slip is usually small, typically between 0.01 and 0.05.

At this point, the motor's torque is relatively stable but not at its maximum.

Relationship Between Slip and Torque

The relationship between slip and torque can be represented by a curve, which is usually parabolic. The peak of the curve corresponds to the maximum torque, where the slip reaches the critical value.

Factors Affecting Slip

Load

When the load increases, the rotor speed decreases, increasing the slip and the torque, until a new equilibrium is established.

If the load exceeds the load corresponding to the maximum torque, the motor will stall.

Rotor Resistance

Increasing the rotor resistance can increase the maximum torque and starting torque, but it will also reduce the motor's efficiency and operating speed.

Supply Voltage

A decrease in supply voltage results in a decrease in rotor current, thereby reducing the torque. Conversely, increasing the supply voltage can increase the torque.

Summary

Slip significantly affects the torque of an AC induction motor. The greater the slip, the greater the torque, up to the point of maximum torque at the critical slip. Understanding the relationship between slip and torque is crucial for correctly selecting and using AC induction motors.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!