What parameters determine the torque of an induction motor?

Encyclopedia
11/08/2024

The torque of an induction motor is influenced by various parameters, mainly including the following aspects:

1. Power supply voltage

The power supply voltage has a significant impact on the torque of an induction motor. According to the operating principle of the motor, the electromagnetic torque is directly proportional to the magnetic flux per pole and the induced current in the rotor, both of which are directly proportional to the voltage. Therefore, a drop in the power supply voltage can significantly affect the starting performance of the motor. For example, if the power supply voltage drops to 80% of its original value, the starting torque will decrease to 64% of its original value.

2. Stator and rotor leakage reactance

The leakage reactance (produced by leakage flux) of the stator and rotor also affects the torque of the motor. The greater the leakage reactance, the smaller the starting torque; conversely, reducing the leakage reactance can increase the starting torque. Leakage reactance is related to the number of turns in the winding and the size of the air gap.

3. Rotor Resistance

Increasing the rotor resistance can also increase the starting torque. For example, for wound-rotor induction motors, an appropriate additional resistance can be connected in series with the rotor winding circuit to improve the starting torque.

4. Motor Design Parameters

The design parameters of the motor, including motor type, armature winding, permanent magnet material, rotor structure and other factors, directly affect the speed and torque of the electric motor.

5. Work Status

The operating conditions of the motor, such as load size, temperature and humidity of the working environment, etc., will also affect its torque.

6. Control Algorithm of the Controller

The control algorithm of the electric motor's controller also affects the speed and torque of the electric motor. Different control algorithms have different effects on the speed and torque of the electric motor.

7. Transmission ratio of the transmission system

The gear ratio of the transmission system also affects the speed and torque of the electric motor. The larger the gear ratio, the lower the speed of the electric motor, but the torque will increase.

In summary, the torque of an induction motor is influenced by various factors, including the supply voltage, stator and rotor leakage reactance, rotor resistance, motor design parameters, operating conditions, control algorithm of the controller, and gear ratio of the transmission system. These factors interact with each other, determining the torque performance of the induction motor under different working conditions.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025