Why does the outer frame of an induction motor have slots on its outer periphery?

Encyclopedia
11/11/2024

The reason for the slots on the outer periphery of the frame of an induction motor.

The outer periphery of the frame of an induction motor is designed with slots, primarily to accommodate and secure the stator winding. The following are the specific reasons and related details:

The installation of the stator winding

The stator winding of an induction motor needs to be installed in the slots of the outer frame (stator core). These slots provide physical support, allowing the windings to be securely fixed in the correct position, thereby ensuring the normal operation of the motor.

Generation and Control of Magnetic Fields

By setting slots on the outer frame periphery and installing windings, a rotating magnetic field can be effectively generated and controlled. The relative motion between this rotating magnetic field and the rotor windings results in the generation of induced electromotive force and current within the rotor windings, which in turn produces electromagnetic torque, driving the motor to rotate.

Improve efficiency and performance

The specific slot design (such as the number of slots, the arrangement of slots, etc.) helps to optimize the performance of the motor. For example, by adjusting the number and configuration of slots, it is possible to reduce the electromagnetic noise during motor operation and improve efficiency.

Conclusion

In summary, the slots on the outer periphery of the frame of an induction motor are designed to install and secure the stator winding. This is done to generate and control the rotating magnetic field, thereby ensuring the normal operation and efficient performance of the motor.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download