How does a compound winding on an AC motor work?

Encyclopedia
11/14/2024

Compound windings (Compound Winding) are a special type of winding commonly used in AC motors, especially in applications requiring improved starting performance and operational efficiency. Compound windings combine the features of the main winding (Main Winding) and the auxiliary winding (Auxiliary Winding) to achieve better performance. Here is a detailed explanation of how compound windings work and their characteristics:

1. Structure of Compound Windings

Compound windings typically consist of two parts:

  • Main Winding: This is the primary winding of the motor, responsible for providing most of the magnetic field and torque during normal operation. The main winding is usually connected in a star (Y) or delta (Δ) configuration.

  • Auxiliary Winding: This is the secondary winding, used to improve the motor's starting performance and operational characteristics. The auxiliary winding is typically connected during startup and disconnected once the motor reaches a certain speed.

2. Working Principle

Starting Phase

  • During Startup: When the motor starts, both the main winding and the auxiliary winding are connected. The auxiliary winding provides an additional magnetic field to help the motor overcome static friction and inertia, allowing it to reach the rated speed more quickly.

  • Starting Current: The presence of the auxiliary winding helps control the starting current, preventing excessive surge currents that could damage the motor or the power grid.

Running Phase

  • After Reaching Rated Speed: Once the motor reaches the predetermined operating speed, the auxiliary winding is disconnected, leaving only the main winding in operation. This reduces energy consumption and improves the motor's operational efficiency.

  • Magnetic Field Superposition: During the starting phase, the magnetic fields generated by the main winding and the auxiliary winding superimpose, creating a stronger resultant magnetic field, which increases the starting torque.

3. Types of Auxiliary Windings

There are several types of auxiliary windings, including:

  • Capacitor Start Winding: During startup, the auxiliary winding is connected through a capacitor, which shifts the phase of the current, thereby increasing the starting torque. After startup, the auxiliary winding is disconnected via a centrifugal switch.

  • Capacitor Run Winding: The auxiliary winding remains connected throughout the entire operation, with the capacitor adjusting the phase to improve the motor's operational characteristics.

  • Resistance Start Winding: The auxiliary winding is connected through a resistor, which limits the starting current. After startup, the auxiliary winding is disconnected via a centrifugal switch.

4. Advantages

  • Improved Starting Performance: Compound windings significantly enhance the motor's starting torque, making it easier to start.

  • Controlled Starting Current: The combination of the auxiliary winding and capacitors effectively controls the starting current, reducing the impact on the power grid.

  • Enhanced Operational Efficiency: Disconnecting the auxiliary winding after startup reduces energy consumption and improves the motor's operational efficiency.

  • Improved Power Factor: The use of capacitors can improve the motor's power factor, reducing reactive power consumption.

5. Applications

Compound windings are widely used in AC motors that require good starting performance and operational efficiency, such as:

  • Household Appliances: Refrigerators, air conditioners, washing machines, etc.

  • Industrial Equipment: Fans, pumps, compressors, etc.

Summary

Compound windings optimize the performance of AC motors during both the starting and running phases by combining the features of the main winding and the auxiliary winding. During startup, the auxiliary winding provides an additional magnetic field to help overcome starting resistance; during operation, the auxiliary winding is disconnected to reduce energy consumption and improve efficiency.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!