Permanent Split Capacitor (PSC) Motor

Edwiin
05/10/2025

The Permanent Split Capacitor (PSC) motor also features a cage rotor, and it has two windings, namely the main winding and the auxiliary winding, which are similar to those in a Capacitor Start motor and a Capacitor Start Capacitor Run motor. However, in a PSC motor, there is only one capacitor that is connected in series with the starting winding. This capacitor remains permanently connected within the circuit, functioning both during the starting process and when the motor is running.

The connection diagram of a Permanent Split Capacitor motor is illustrated as follows:

image.png

It is also known as a Single Value Capacitor motor. Since the capacitor remains constantly in the circuit, this type of motor does not incorporate any starting switch. The auxiliary winding is always present in the circuit. As a result, the motor functions as a balanced two-phase motor, generating a uniform torque and operating without noise.

Advantages of Permanent Split Capacitor (PSC) Motor

The Single Value Capacitor motor offers the following benefits:

  • There is no requirement for a centrifugal switch.
  • It has a high efficiency.
  • With the capacitor permanently connected in the circuit, it exhibits a high power factor.
  • It possesses a relatively high pullout torque.

Limitations of Permanent Split Capacitor (PSC) Motor

The limitations of this motor are as follows:

In this motor, a paper capacitor is utilized because an electrolytic capacitor cannot be used for continuous operation. The cost of the paper capacitor is higher, and its size is larger compared to an electrolytic capacitor of the same rating.

It has a low starting torque, which is less than the full load torque.

Applications of Permanent Split Capacitor (PSC) Motor

The Permanent Split Capacitor motor has diverse applications, as listed below:

  • It is used in fans and blowers of heaters and air conditioners.
  • It is employed in the compressors of refrigerators.
  • It is applied in office machinery.

This concludes the introduction to the Permanent Split Capacitor (PSC) motor.

Edwiin

Hello,I'm Wdwiin. A decade of hands-on experience in electrical engineering, specializing in high-voltage systems, smart grids, and renewable energy technologies. Passionate about technical exchange and knowledge sharing, committed to interpreting industry trends with professional insights to empower peers. Connection creates value—let’s explore the boundless possibilities of the electrical world together!

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec