What is the power angle and load in the case of a synchronous motor?

Encyclopedia
11/25/2024

Power Angle and Load in Synchronous Motors

The power angle (Power Angle) and load in synchronous motors have a close relationship. Understanding these concepts helps to better grasp the working principle and performance of synchronous motors. Here is a detailed explanation:

1. Power Angle (Power Angle)

Definition

Power Angle (also known as torque angle or electric angle, denoted as δ) is the phase difference between the rotor magnetic field axis and the stator magnetic field axis. It represents the position of the rotor magnetic field relative to the stator magnetic field.

Impact

  • Power Transfer: The power angle directly affects the active power absorbed by the synchronous motor from the grid. The larger the power angle, the more active power the motor absorbs.

  • Stability: An excessively large power angle can cause the motor to lose synchronization, leading to a "slip" phenomenon.

2. Load

Definition

Load refers to the mechanical load driven by the synchronous motor, typically expressed in power units (kilowatts or horsepower).

Relationship

Power Angle and Load Relationship: The power angle δ and the load P of a synchronous motor have a nonlinear relationship, which can be expressed by the following formula:

e9b7f280c00f91f23a42617692f3a6a9.jpeg

Where:

  • P is the active power absorbed by the motor (watts or kilowatts).

  • E is the no-load EMF (electromotive force) of the motor (volts).

  • V is the grid voltage (volts).

  • Xs is the synchronous reactance of the motor (ohms).

  • δ is the power angle (radians).

3. Graphical Representation of Power Angle Characteristics

Characteristics Curve

  • Characteristics Curve: The relationship between power angle and load can be represented by a characteristic curve. This curve is typically nonlinear and follows a sine function.

  • Maximum Power Point: When the power angle δ reaches 90 degrees (π/2 radians), the motor absorbs the maximum active power Pmax :

33bf6ca92d98fe5cb6dbc986a65e0938.jpeg

Slip Point: When the power angle exceeds 90 degrees, the motor may lose synchronization, leading to a "slip" condition.

4. Influencing Factors

Grid Voltage

Voltage Variation: Changes in grid voltage V affect the relationship between the power angle and load. An increase in voltage allows the motor to absorb more active power.

Motor Parameters

Synchronous Reactance: Synchronous reactance Xs  is an important internal parameter of the motor, affecting the relationship between power angle and load. A higher synchronous reactance results in less active power absorption by the motor.

Load Variation

Increase in Load: When the load increases, the motor automatically adjusts the power angle to absorb more active power until a new equilibrium point is reached.

5. Summary

  • Power Angle δ: Represents the phase difference between the rotor magnetic field and the stator magnetic field, directly influencing the active power absorbed by the motor.

  • Load P: The mechanical load driven by the motor, having a nonlinear relationship with the power angle.

  • Relationship Formula: P=(EV/Xs) sin(δ) describes the relationship between power angle and load.

  • Maximum Power Point: When the power angle δ reaches 90 degrees, the motor absorbs the maximum active power Pmax=EV/ Xs.

  • Slip Point: When the power angle exceeds 90 degrees, the motor may lose synchronization.

Understanding these concepts helps to better design and operate synchronous motors, ensuring their stable operation under various conditions. 

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!