What is a Current Transformer ?

Encyclopedia
08/08/2024

What is a  Current Transformer ?

Current Transformer Definition

A current transformer (CT) is defined as an instrument transformer where the secondary current is proportional to the primary current and ideally has zero phase difference.

2850880b-827f-482b-81b0-5837ea95a4f9.jpg

CT Accuracy Clas

The accuracy class of a current transformer measures how accurately the CT replicates the primary current in its secondary, crucial for precise metering.

Working Principle

Current transformers operate on the principle of a power transformer, where the primary current is the system current, and the secondary current depends on the primary current.

Ratio Error in Current Transformer

Ratio error in current transformer occurs when the primary current isn’t perfectly mirrored in the secondary current due to core excitation.

146cf536-554b-4a20-a9c6-5173803b559c.jpg

  • Is – Secondary current.

  • Es – Secondary induced emf.

  • Ip – Primary current.

  • Ep – Primary induced emf.

  • KT – Turns ratio = Numbers of secondary turns/number of primary turns.

  • I0 – Excitation current.

  • Im – Magnetizing component of I0.

  • Iw – Core loss component of I0.

  • Φm – Main flux.

427eaa09-46ae-4eb7-bc86-d4cfed80500d.jpg

Reducing CT Errors

  • Using a core of high permeability and low hysteresis loss magnetic materials.

  • Keeping the rated burden to the nearer value of the actual burden.

  • Ensuring minimum length of flux path and increasing cross-sectional area of the core, minimizing joint of the core.

  • Lowering the secondary internal impedance.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!