Can you explain the difference between UPS and inverter? How many types of UPS exist?

Encyclopedia
10/07/2024

Differences between UPS and inverter


Definition and Role of UPS


UPS, which stands for Uninterruptible Power Supply, is a constant voltage and frequency power supply that contains storage devices and is mainly composed of inverters. Its main function is to provide stable and uninterrupted power supply for computers and their network systems or other power electronic devices.


Inverter Definition and Function


An inverter is a power conversion device primarily used for converting DC power into AC power. It comprises a DC input and an AC output, converting DC electricity into AC electricity through the process of inversion to supply AC loads. Inverters can provide AC power with different voltages, frequencies, and powers as required.


The main difference between UPS and inverter


  • Functional Differences: A UPS contains not only the function of an inverter but also a battery pack, enabling it to provide continuous power supply when there is an external power failure or blackout. An inverter only performs power conversion and has no power storage function, so it cannot provide continued power supply during a power outage.


  • Battery Configuration: The UPS has an integrated battery pack that can provide emergency power during a power outage; whereas the inverter does not have an internal battery and usually requires an external power source or battery pack.


  • Application Scenarios: UPS is suitable for scenarios where critical equipment and data need to be protected, and where there are high requirements for power quality. Inverters, on the other hand, are applicable for converting DC power into AC power, and are suitable for solar power generation systems, wind power generation systems, electric vehicle charging, and wireless communication fields.



Types of UPS


UPS can be divided into three types according to its working principle: backup, online, and interactive.


  • Backup UPS: In normal conditions, it is in the state of charging the battery. When there is a power outage, the inverter switches to operation mode urgently, converting the direct current provided by the battery into stable alternating current output. The advantages of a backup UPS are high operating efficiency, low noise, and relatively cheap price. It is mainly suitable for scenarios where the fluctuation of the city's electricity is not significant and the requirements for power quality are not high.


  • Online UPS: This type of UPS keeps its inverter in operation at all times. It first converts external AC power into DC power through a circuit, and then uses a high-quality inverter to convert the DC power into high-quality sine wave AC power output to the computer. The online UPS is suitable for applications with strict power requirements, such as computers, transportation, banking, securities, communication, medical, and industrial control industries.


  • Online Interactive UPS: This is an intelligent UPS that operates with its inverter in reverse mode when the input city power is normal, charging the battery pack; when the city power is abnormal, the inverter immediately switches to inversion mode, converting the battery pack's energy into alternating current output. The advantage of an online interactive UPS is its strong software functionality, allowing for convenient remote control and intelligent management.



Conclusion


In summary, there are significant differences between UPS and inverters in terms of functionality, battery configuration, and application scenarios. If you need a device that can provide continuous power supply and protect critical equipment, then a UPS is a more suitable choice. If you only need to convert DC power into AC power and do not have the demand for continuous power supply, then an inverter may be a more cost-effective solution. Based on your specific needs and application scenarios, you can choose the most suitable equipment.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!