What Does Capacitance Depend On?

The capacitance (C) of a capacitor depends on several main factors:

Plate Area (A):

The capacitance increases with the area of the plates. Larger plates can hold more charge.

Mathematically, this is expressed as C∝A.

Plate Separation (d):

The capacitance decreases as the distance between the plates increases. A smaller distance allows for a stronger electric field, enabling the storage of more charge.

Mathematically, this is expressed as C∝ 1/d .

Dielectric Constant (ε):

The dielectric constant (also known as relative permittivity or dielectric constant) of the material between the plates affects the capacitance. A higher dielectric constant results in a larger capacitance. The dielectric constant is a dimensionless number that indicates the material's ability to store electrical energy relative to a vacuum.Mathematically, this is expressed as C∝ε.

Combining these factors, the capacitance of a parallel plate capacitor can be expressed by the formula:C=εrε0A/d

where:


  • C is the capacitance, measured in farads (F).


  • εr is the relative dielectric constant of the material.


  • ε0 is the permittivity of free space, approximately  8.854 × 1 0 12 F/m 8.854×10−12F/m.

  • A is the area of the plates, measured in square meters (m²).


  • d is the separation between the plates, measured in meters (m).

Example

Consider a parallel plate capacitor with a plate area of 0.01 m 2 0.01m2, a plate separation of 0.001 m 0.001m, and a dielectric material with a relative dielectric constant of 2. The capacitance of this capacitor can be calculated as follows:

04cad2e7ca0e685bffad38ef96d6386b.jpeg

Therefore, the capacitance of this capacitor is 177.08 picofarads (pF).

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!