What are the factors that affect the torque produced by an electric motor?

Encyclopedia
11/15/2024

The factors affecting the torque generated by an electric motor mainly include the following aspects:

1. Power Supply Voltage

Voltage Level: The torque of an electric motor is directly proportional to the square of the supply voltage. The higher the voltage, the greater the torque produced by the motor. Conversely, a drop in voltage leads to a significant decrease in torque. For instance, if the supply voltage drops to 80% of its original value, the starting torque will decrease to 64% of its original value.

2. Current

Current: Current is the main energy source that drives the motor to operate. The larger the current, the greater the torque of the motor.

3. Number of Poles in the Motor

Pole Number: The higher the number of poles in a motor, the greater the torque it produces. This is because, under the same conditions, a motor with more poles can generate a stronger magnetic field, thereby increasing torque.

4. Motor Materials and Quality

Material Quality: High-quality motor materials and larger motor mass can improve the torque performance of the motor.

5. The heat dissipation effect of the motor

Cooling Effect: A good cooling effect can ensure that the motor operates normally at high temperatures, improving its torque performance.

6. Load Status

Load Size: The larger the load, the greater the torque required by the motor, but the speed will decrease. Conversely, the smaller the load, the less torque the motor needs and the higher the speed.

7. Environmental Conditions

Temperature and Humidity: The higher the ambient temperature, the lower the speed and torque of the electric motor; high humidity may affect the insulation performance of the electric motor, thereby affecting its performance.

8. Control Algorithm of the Controller

Control Algorithm: Different control algorithms (such as current control, speed control, position control, etc.) have varying effects on the speed and torque of an electric motor.

9. Transmission System Gear Ratio

Transmission Ratio: The larger the transmission ratio, the lower the speed of the electric motor, but the torque will increase.

10. Design Parameters of Electric Motor

Design Parameters: These include factors such as motor type, armature winding, permanent magnet material, rotor structure, etc., which directly affect the speed and torque of the electric motor.

11. Leakage Reactance

Leakage reactance:High leakage reactance (caused by leakage magnetic flux) results in low starting torque; reducing leakage reactance can increase starting torque. Leakage reactance is related to the number of turns in the winding and the size of the air gap.

12. Rotor Resistance

Rotor Resistance: Increasing the rotor resistance can enhance the starting torque. For instance, when starting a wound-rotor induction motor, adding an appropriate amount of additional resistance in series with the rotor winding circuit can increase the starting torque.

In summary, the torque of an electric motor is affected by a combination of various factors, including the supply voltage and current, the number of poles of the motor, material and mass, heat dissipation performance, load conditions, environmental conditions, control algorithms of the controller, gear ratio of the transmission system, design parameters of the motor, leakage reactance, and rotor resistance, among others. In practical applications, it is necessary to consider these factors comprehensively to select and design appropriate electric motors, ensuring that their performance and efficiency reach optimal levels.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!