What is the relationship between inductance and the number of turns in a coil?

Encyclopedia
11/15/2024

What is the relationship between inductance and the number of turns in a coil?

The inductance (Inductance) has a direct relationship with the number of turns (Number of Turns) in a coil. Specifically, the inductance 

L is proportional to the square of the number of turns N. This relationship can be expressed by the following formula:

6f87067bca8e10c30039c94bbafed00b.jpeg

where:

  • L is the inductance (unit: Henry, H)

  • N is the number of turns in the coil

  • μ is the permeability (unit: Henry/meter, H/m)

  • A is the cross-sectional area of the coil (unit: square meters, m²)

  • l is the length of the coil (unit: meters, m)

Explanation

Number of Turns 

N:The more turns in the coil, the greater the inductance. This is because each additional turn increases the magnetic field strength, thus increasing the stored magnetic energy. Therefore, the inductance is proportional to the square of the number of turns.

Permeability 

μ:Permeability is the magnetic property of the material. Different materials have different permeabilities. High-permeability materials (such as ferrite or iron cores) can enhance the magnetic field, thereby increasing the inductance.

Cross-sectional Area 

A:The larger the cross-sectional area of the coil, the greater the inductance. This is because a larger cross-sectional area can accommodate more magnetic flux.

Length of the Coil 

l:The longer the coil, the smaller the inductance. This is because a longer coil means the magnetic flux is distributed more widely, reducing the magnetic energy density per unit length.

Practical Applications

In practical applications, the inductance can be precisely controlled by adjusting the number of turns in the coil, selecting appropriate core materials, and changing the geometry of the coil. For example, in radio engineering, power filtering, and signal processing, the precise design of inductors is very important.

In summary, the inductance is proportional to the square of the number of turns in the coil, a relationship determined by fundamental principles of electromagnetism. By designing appropriately, the desired inductance value can be achieved.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!