Duty Cycle of Motor

Encyclopedia
08/21/2024

Motor Duty Class Definition

Nowadays, electric motors are used in almost every application, controlled by electrical drives. However, not all motors operate for the same amount of time. Some run continuously, while others have shorter run times with longer rest periods. This difference introduces the concept of motor duty class, which divides motor duty cycles into eight categories:

  • Continuous duty

  • Short time duty

  • Intermittent periodic duty

  • Intermittent periodic duty with starting

  • Intermittent periodic duty with starting and braking

  • Continuous duty with intermittent periodic loading

  • Continuous duty with starting and braking

  • Continuous duty with periodic speed changes

da2c812c4944b95ef71d5a19d491a39c.jpeg

Continuous Duty

This duty denotes that, the motor is running long enough AND the electric motor temperature reaches the steady state value. These motors are used in paper mill drives, compressors, conveyors etc.

6b7837f7f3dc7763f134cd9d34f834d4.jpeg

Short Time Duty

These motors operate for short periods, and their heating time is much less than their cooling time. Thus, the motor cools down to ambient temperature before operating again. These motors are used in crane drives, household appliances, and valve drives.

e85c74fb492a114969d63fa08289fe01.jpeg

468b5426d82f7f75357e8408609de83a.jpeg 


c02bbd3efe262921592ac61121ac6d4d.jpeg

Intermittent Periodic Duty

In this duty, the motor runs for a while and then rests. Neither period is long enough to reach steady state temperature or cool down completely. This type is used in press and drilling machine drives.

Intermittent Period Duty with Starting

In this type of drives, heat loss during starting and braking cannot be ignored. So, the corresponding periods are starting period, operating period, braking period and resting period, but all the periods are too short to attain the respective steady state temperatures, these techniques are used in billet mill drive, manipulator drive, mine hoist etc.

Continuous Duty with Intermittent Periodic Loading

This motor duty is similar to periodic duty, but it includes a no-load running period instead of a rest period. Examples include pressing and cutting machines.

Continuous Duty with Starting and Braking

It is also a period of starting, running and braking and there is no resting period. The main drive of a blooming mill is an example.

Continuous Duty with Periodic Speed Changes

In this type of motor duty, there are different running periods at different loads and speeds. But there is no rest period and all the periods are too short to attain the steady state temperatures.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!