What is a Centrifugal Switch?

Encyclopedia
08/12/2024

What is a Centrifugal Switch?

Centrifugal Switch Definition

A centrifugal switch is an electrical component that activates based on the centrifugal force generated by a motor’s rotating shaft to control motor start-up.

ba4c7134b72443a511ff9a60f0723a72.jpeg 

Operational Mechanism

A single-phase AC engine has a centrifugal switch inside its case, which is attached to the engine shaft. When the engine is off and motionless, the switch is closed.

When the engine is switched on, the switch drives electricity to the capacitor and the extra coil winding in the engine, increasing its starting torque. As the engine’s revolutions increase per minute, the switch opens, as the engine no longer needs a boost.

A centrifugal switch solves a problem associated with single-phase AC electric motors. They do not develop enough torque on their own to start turning from a dead stop.

A circuit switches on the centrifugal switch, providing the requisite boost to start the motor. The switch turns off the boost circuit until the motor reaches its running speed, and the motor runs normally.

Symbol and Schematic

The symbol of a centrifugal switch in electrical schematics represents its function and connection within an electrical or electronic circuit.

1cf5e9ca8a33684ed227805f6ea4e5ac.jpeg

Testing Protocols

  • Throughout its life cycle, the process should be uniform.

  • For simplicity of design and low production cost, the number of components of the equipment should be minimal.

  • It should have marginal elements of friction.

  • Without causing any significant design changes, the cut-out/cut-in ratio should be readily modifiable.

  • The switch is readily accessible as the communication unit of the switch is present on the outside of the motor frame. So, without dismantling the motor assembly, the switch can be tested, washed, and replaced.

Impact of Malfunction

If the centrifugal switch fails to disconnect after the motor starts, it can cause the starting winding to burn out, highlighting the importance of proper switch function for motor longevity.

Applications of a Centrifugal Switch

  • Defense against Overspeed in motors, generators, etc.

  • Used in DC motors, conveyors, escalators, lifts, etc.

  • These are also used in devices such as blowers, fans as well as conveyors to detect under-speed.

  • Material losses are often used in systems where the loss of speed could lead to damage of the device.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!