Speed Control of a Synchronous Motor

Encyclopedia
08/16/2024

Synchronous Motor Definition

Synchronous motors are defined as constant speed motors that run at the synchronous speed of the supply. They are typically used for constant speed operations and to improve the power factor under no load conditions. Synchronous motors also have fewer losses compared to induction motors of the same rating.

The speed of a synchronous motor is given by

c01666128637897756451827208cc42a.jpeg

 Where, f = supply frequency and p = number of poles.

The synchronous speed depends on the supply frequency and the number of poles on the rotor. Since changing the number of poles is difficult, it’s not used. However, with solid-state devices, we can vary the current frequency to the synchronous motor. This allows us to control the motor’s speed by changing the supply frequency.

Speed Control Factors

The speed of a synchronous motor depends on the supply frequency and the number of poles, with frequency adjustment being the practical method for speed control.

Open Loop Control

Inverter fed open loop synchronous motor drive uses variable frequency without feedback, suitable for less precise speed control needs.

04a9d0019ef98a999831480359c21da5.jpeg

Closed Loop Operation

Self-synchronous (closed-loop) operation provides accurate speed control by adjusting frequency based on rotor speed feedback, avoiding oscillations.

a6ed8a315da42fa26cdf3c75e5e3e1fe.jpeg

Speed Control of Synchronous Motor

Speed control of synchronous motor is achieved through varying the supply frequency using solid-state devices, rectifiers, and inverters.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!