Characteristics of Series Wound DC Generator

Encyclopedia
08/20/2024

Series Generator Definition

A series wound DC generator is defined as a generator where the field windings, armature windings, and external load circuit are connected in series, causing the same current to flow through each part.

6384c2c4ed7e37c553f19ff196067cd0.jpeg

 In these types of generators the field windings, armature windings and external load circuit all are connected in series as shown in figure below.

Therefore, the same current flows through armature winding, field winding and the load.

Let, I = Ia = Isc = IL

Here, Ia = armature current

Isc = series field current

IL = load current

There are generally three most important characteristics of series wound DC generator which show the relation between various quantities such as series field current or excitation current, generated voltage, terminal voltage and load current.

Magnetic Characteristic Curve

The curve which shows the relation between no load voltage and the field excitation current is called magnetic or open circuit characteristic curve. As during no load, the load terminals are open circuited, there will be no field current in the field since, the armature, field and load are series connected and these three make a closed loop of circuit. So, this curve can be obtained practically be separating the field winding and exciting the DC generator by an external source.

In the diagram, the AB curve shows the magnetic characteristic of a series wound DC generator. The curve is linear until the poles reach saturation. After this point, the terminal voltage doesn’t increase significantly with additional field current. Due to residual magnetism, there is an initial voltage across the armature, so the curve starts slightly above the origin at point A.

Internal Characteristic Curve

The internal characteristic curve shows the relationship between the voltage generated in the armature and the load current. This curve accounts for the drop caused by the armature reaction’s demagnetizing effect, making the actual generated voltage (Eg) less than the no-load voltage (E0). Therefore, the curve drops slightly from the open circuit characteristic curve. In the diagram, the OC curve represents this internal characteristic.

External Characteristic Curve

8b10a3e22241adc27b8a7e58dcfcf090.jpeg

The external characteristic curve shows the variation of terminal voltage (V) with the load current (IL). Terminal voltage of this type of generator is obtained by subtracting the ohomic drop due to armature resistance (Ra) and series field resistance (Rsc) from the actually generated voltage (Eg).

Terminal voltage V = Eg – I(Ra + Rsc)

The external characteristic curve lies below the internal characteristic curve because the value of terminal voltage is less than the generated voltage. Here in the figure OD curve is showing the external characteristic of the series wound DC generator.

From the characteristics of a series wound DC generator, we can see that as the load increases (and therefore the load current), the terminal voltage initially rises. However, after reaching a peak, it starts to decrease due to the demagnetizing effect of the armature reaction. The dotted line in the figure shows this phenomenon, indicating that the current remains roughly constant despite changes in load resistance. When the load increases, so does the field current, as the field is series connected with the load. Similarly, the armature current increases as it is also series connected. However, due to saturation, the magnetic field strength and induced voltage do not significantly increase. The increased armature current leads to a greater armature reaction, causing a drop in load voltage. If the load voltage drops, the load current also decreases, as current is proportional to voltage (Ohm’s law). These simultaneous effects mean there is no significant change in load current in the dotted portion of the external characteristic curve. This behavior makes the series DC generator a constant current generator.

Constant Current Generator

A series wound DC generator is known as a constant current generator because the load current remains nearly constant despite variations in load resistance.

Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!