What is a Solid-State Transformer? 2025Tech, Structure & Principles Explained

Noah
Noah
Field: Design & Maintenance
Australia

1. What is a Solid-State Transformer (SST)?

1.1 Fundamentals and Limitations of Conventional Transformers

The article first reviews the history (e.g., Stanley's 1886 patent) and basic principles of conventional transformers. Based on electromagnetic induction, traditional transformers consist of silicon steel cores, copper or aluminum windings, and insulation/cooling systems (mineral oil or dry-type). They operate at fixed frequencies (50/60 Hz or 16⅔ Hz), with fixed voltage transformation ratios, power transfer capabilities, and frequency characteristics.

Advantages of conventional transformers:

  • Low cost

  • High reliability (efficiency >99%)

  • Short-circuit current limiting capability

Disadvantages include:

  • Large size and heavy weight

  • Sensitive to harmonics and DC bias

  • No overload protection

  • Fire and environmental risks

1.2 Definition and Origin of Solid-State Transformers

A Solid-State Transformer (SST) is an alternative to conventional transformers based on power electronics technology, with origins tracing back to McMurray's "electronic transformer" concept in 1968. SSTs achieve voltage transformation and galvanic isolation through a Medium-Frequency (MF) isolation stage, while also providing multiple intelligent control functions.

Basic structure of an SST includes:

  • Medium-Voltage (MV) interface

  • Medium-Frequency (MF) isolation stage

  • Communication and control links

SST.jpg

2. Design Challenges of SSTs

2.1 Challenge: Handling Medium Voltage (MV)

Medium-voltage levels (e.g., 10 kV) far exceed the voltage ratings of existing semiconductor devices (Si IGBTs up to 6.5 kV, SiC MOSFETs ~10–15 kV). Therefore, either a multi-cell (modular) or single-cell (high-voltage device) approach must be adopted.

Advantages of multi-cell solutions:

  • Modular and redundant design

  • Multi-level output waveforms, reducing filter requirements

  • Support for hot-swapping and fault tolerance

Advantages of single-cell solutions:

  • Simpler structure

  • Suitable for three-phase systems

2.2 Challenge: Topology Selection

SST topologies can be categorized as:

  • Isolated Front-End (IFE): Isolation before rectification

  • Isolated Back-End (IBE): Rectification before isolation

  • Matrix converter type: Direct AC-AC conversion

  • Modular Multilevel Converter (M2LC)

2.3 Challenge: Reliability

Conventional transformers are extremely reliable, whereas SSTs incorporate numerous semiconductors, control circuits, and cooling systems, making reliability a critical concern. The paper introduces Reliability Block Diagrams (RBD) and failure rate (λ in FIT) models, indicating that redundancy can significantly improve system reliability.

2.4 Challenge: Medium-Frequency Isolated Power Converters

Common topologies include:

  • Dual Active Bridge (DAB): Power flow controlled via phase shift, enabling soft switching

  • Half-Cycle Discontinuous Mode Series Resonant Converter (HC-DCM SRC): Achieves ZCS/ZVS, exhibiting "DC transformer" characteristics

2.5 Challenge: Medium-Frequency Transformer Design

Medium-frequency transformers operate at kHz-level frequencies, facing challenges such as:

  • Smaller magnetic core volume

  • Conflict between insulation and thermal management

  • Uneven current distribution in Litz wire

2.6 Challenge: Isolation Coordination

Medium-voltage units require high insulation to ground, necessitating consideration of:

  • Combined 50 Hz power frequency and medium-frequency electric field stress

  • Dielectric losses and risk of localized overheating

2.7 Challenge: Electromagnetic Interference (EMI)

Common-mode currents generated during MV switching can flow to ground through parasitic capacitance and must be suppressed using common-mode chokes.

2.8 Challenge: Protection

SSTs must handle overvoltage, overcurrent, lightning strikes, and short circuits. Traditional fuses and surge arresters remain applicable but should be combined with electronic current limiting and energy absorption strategies.

SST.jpg

2.9 Challenge: Control

SST control systems are complex and require a hierarchical structure:

  • External control: Grid interaction, power dispatch

  • Internal control: Voltage/current regulation, redundancy management

  • Unit-level control: Modulation and protection

2.10 Challenge: Construction of Modular Converters

Building practical MV modular systems involves:

  • Insulation design

  • Cooling systems

  • Communication and auxiliary power

  • Mechanical structure and hot-swappable support

2.11 Challenge: Testing of MV Converters

MV testing facilities are complex and require:

  • High-voltage, high-power sources/loads

  • High-precision measurement equipment (e.g., high-voltage differential probes)

  • Backup test strategies (e.g., back-to-back testing)

3. Applicability and Use Cases of SSTs

3.1 Grid Applications

SSTs can be used in power grids for:

  • Voltage regulation and reactive power compensation

  • Harmonic filtering and power quality improvement

  • DC interface integration (e.g., energy storage, photovoltaics)

However, compared to conventional Line Frequency Transformers (LFTs), SSTs face an "efficiency challenge":

  • LFT efficiency can reach 98.7%

  • SSTs typically achieve only ~96.3% due to multi-stage conversion

  • Limited reduction in size and weight (~2.6 m³ vs. 3.4 m³)

  • Significantly higher cost (>52.7k USD vs. 11.3k USD)

3.2 Traction Applications

Traction systems (e.g., electric locomotives) have stringent requirements for size, weight, and efficiency, where SSTs offer clear advantages:

  • Significantly reduced transformer size through higher operating frequencies (e.g., 20 kHz)

  • Dual optimization of efficiency and volume reduction

3.3 DC-DC Applications

In DC systems (e.g., offshore wind power collection, data centers), SSTs are the only viable isolation solution, as their operating frequency can be freely chosen without being constrained by grid frequency.

4. Future Concepts and Conclusion

4.1 Future Application Scenarios

  • Subsea oil & gas processing systems

  • Airborne wind turbines

  • All-electric aircraft

  • Naval medium-voltage DC (MVDC) systems

Give a tip and encourage the author!
Recommended
How to Identify Internal Faults in a Transformer?
How to Identify Internal Faults in a Transformer?
Measure DC resistance: Use a bridge to measure the DC resistance of each high- and low-voltage winding. Check whether the resistance values among phases are balanced and consistent with the manufacturer’s original data. If phase resistance cannot be measured directly, line resistance may be measured instead. The DC resistance values can indicate whether the windings are intact, whether there are short circuits or open circuits, and whether the contact resistance of the tap changer is normal. If
Felix Spark
11/04/2025
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
What are the requirements for inspecting and maintaining a transformer's no-load tap changer?
The tap changer operating handle shall be equipped with a protective cover. The flange at the handle shall be well sealed with no oil leakage. Locking screws shall securely fasten both the handle and the drive mechanism, and the handle rotation shall be smooth without binding. The position indicator on the handle shall be clear, accurate, and consistent with the tap voltage regulation range of the winding. Limit stops shall be provided at both extreme positions. The insulating cylinder of the t
Leon
11/04/2025
How to Overhaul a Transformer Conservator (Oil Pillow)?
How to Overhaul a Transformer Conservator (Oil Pillow)?
Overhaul Items for Transformer Conservator:1. Ordinary-Type Conservator Remove the end covers on both sides of the conservator, clean rust and oil deposits from inner and outer surfaces, then apply insulating varnish to the inner wall and paint to the outer wall; Clean components such as the dirt collector, oil level gauge, and oil plug; Check that the connecting pipe between the explosion-proof device and the conservator is unobstructed; Replace all sealing gaskets to ensure good sealing with n
Felix Spark
11/04/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application