What is tha Impulse Test of Transformer?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

The purpose of the pulse test

Detection of partial discharge

Partial discharge refers to the discharge phenomenon that occurs at the air gap or impurity in the insulation material under the action of high voltage electric field, which may gradually destroy the insulation system.

Evaluate the degree of insulation aging

By analyzing the characteristics of partial discharge, you can evaluate the degree of aging of the insulation material.

Identify potential insulation failures

Problems such as moisture, filth, bubbles, or mechanical damage.

Method of pulse test

Pulse Current Method (PCM) 

Principle: By applying a short high-voltage pulse, the partial discharge inside the transformer is excited, and the pulse current generated by the partial discharge is captured.

Equipment: Using a pulse current tester, this instrument is capable of generating high voltage pulses and capturing current pulses generated by partial discharge.

Procedure

  • Disconnect the power supply to the transformer.

  • Connect the pulse current tester to the winding of the transformer.

  • A high voltage pulse is applied and the current pulse generated by the partial discharge is captured.

  • The pulse current waveform is analyzed to determine the characteristics of partial discharge.

Pulse Voltage Method (PVM) 

Principle: By applying high voltage pulse, the partial discharge is excited and the voltage change generated by the partial discharge is captured.

Equipment: Using a pulse voltage tester, this instrument is capable of generating high voltage pulses and capturing voltage changes generated by partial discharge.

Procedure

  • Disconnect the power supply to the transformer.

  • Connect the pulse voltage tester to the winding of the transformer.

  • A high-voltage pulse is applied and the voltage change generated by the partial discharge is captured.

  • The voltage waveform is analyzed to determine the characteristics of partial discharge.

Test considerations

Safety first: Since high pressure is involved, safety procedures must be strictly followed during testing.

Environmental conditions: The test should be carried out in a dry, dust-free environment to reduce external interference.

Equipment calibration: Test equipment should be calibrated regularly to ensure the accuracy of test results.

Data analysis

Partial discharge level: The severity of partial discharge can be assessed by analyzing the amplitude and frequency distribution of pulsed current or voltage.

Pattern recognition: Through pattern recognition technology, different types of partial discharge can be distinguished, so as to locate the cause of the fault.

Trend analysis: Through trend analysis of data from multiple tests, it is possible to monitor changes in the health of the transformer insulation system over time.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
Rectifier vs Power Transformer: Key Differences
Rectifier vs Power Transformer: Key Differences
Differences Between Rectifier Transformers and Power TransformersRectifier transformers and power transformers both belong to the transformer family, but they differ fundamentally in application and functional characteristics. The transformers commonly seen on utility poles are typically power transformers, while those supplying electrolytic cells or electroplating equipment in factories are usually rectifier transformers. Understanding their differences requires examining three aspects: working
Echo
10/27/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Upgrade Traditional Transformers: Amorphous or Solid-State?
Upgrade Traditional Transformers: Amorphous or Solid-State?
I. Core Innovation: A Dual Revolution in Materials and StructureTwo key innovations:Material Innovation: Amorphous AlloyWhat it is: A metallic material formed by ultra-rapid solidification, featuring a disordered, non-crystalline atomic structure.Key Advantage: Extremely low core loss (no-load loss), which is 60%–80% lower than that of traditional silicon steel transformers.Why it matters: No-load loss occurs continuously, 24/7, throughout a transformer’s lifecycle. For transformers with low loa
Echo
10/27/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.