Automatic Voltage Regulator

The automatic voltage regulator (AVR) is an essential device designed to regulate voltage levels. It takes fluctuating voltages and converts them into a stable, constant voltage. Voltage fluctuations primarily occur due to variations in the load on the supply system. Such voltage variations can be detrimental to the equipment within the power system, potentially causing malfunctions or even permanent damage.

To control these voltage variations, voltage - control equipment can be installed at multiple key locations within the power system, such as near transformers, generators, and feeders. In fact, voltage regulators are often deployed at more than one point in the power system to effectively manage voltage fluctuations.

Voltage Control in DC and AC Systems

  • DC Supply System: In a DC supply system, when dealing with feeders of equal length, over - compound generators can be used to control the voltage. However, for feeders of different lengths, a feeder booster is employed to maintain a constant voltage at the end of each feeder.

  • AC System: In an AC system, voltage control can be achieved through various methods. These include the use of booster transformers, induction regulators, and shunt condensers, among others. Each method has its own advantages and is selected based on the specific requirements of the power system.

Working Principle of the Voltage Regulator

The voltage regulator operates on the principle of error detection. First, the output voltage of an AC generator is obtained via a potential transformer. This voltage is then rectified and filtered before being compared to a reference voltage. The difference between the actual voltage and the reference voltage is termed the error voltage. This error voltage is amplified by an amplifier and subsequently supplied to either the main exciter or the pilot exciter. By adjusting the excitation based on this amplified error voltage, the voltage regulator effectively controls and stabilizes the output voltage of the generator, ensuring a consistent and reliable power supply.

image.png

Consequently, the amplified error signals regulate the excitation of the main or pilot exciter through a buck or boost mechanism. This, in turn, controls voltage fluctuations. By controlling the exciter output, the terminal voltage of the main alternator is effectively regulated.

Applications of the Automatic Voltage Regulator

The automatic voltage regulator (AVR) serves several crucial functions:

  • Voltage Control and Stability Enhancement: It maintains the voltage of the power system within acceptable limits and enables the machine to operate closer to the steady - state stability boundary. This ensures reliable power supply and prevents voltage - related instabilities in the system.

  • Reactive Load Sharing: When multiple alternators are operating in parallel, the AVR plays a key role in distributing the reactive load among them. This helps in optimizing the performance of the parallel - operating alternators and maintaining the overall power factor of the system.

  • Overvoltage Mitigation: The AVR is effective in reducing overvoltages that occur due to sudden load shedding in the system. By quickly adjusting the excitation, it prevents excessive voltage rises that could damage electrical equipment.

  • Fault - Time Excitation Adjustment: Under fault conditions, the AVR increases the excitation of the system. This ensures that the maximum synchronizing power is available during the clearance of the fault, facilitating a smoother recovery of the system.

  • Load - Following Excitation Control: When there is a sudden change in the load on the alternator, the AVR adjusts the excitation system. It ensures that the alternator continues to supply the same voltage under the new load conditions. The AVR achieves this by operating on the exciter field, modifying the exciter output voltage and the field current. However, during severe voltage fluctuations, the standard AVR may not respond rapidly enough.

Quick - Acting Voltage Regulators

To achieve a faster response, quick - acting voltage regulators based on the overshooting - the - mark principle are employed. In this principle, when the load increases, the excitation of the system is also increased. But before the voltage reaches the value corresponding to the increased excitation, the regulator anticipates and reduces the excitation to the appropriate level. This overshoot - and - correct mechanism allows for a more rapid and precise adjustment of the voltage, enhancing the performance of the power system during dynamic load changes.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
How Does Power Dispatching Ensure Grid Stability and Efficiency?
How Does Power Dispatching Ensure Grid Stability and Efficiency?
Electric Power Dispatching in Modern Power SystemsThe power system is a critical infrastructure of modern society, providing essential electrical energy for industrial, commercial, and residential use. As the core of power system operation and management, electric power dispatching aims to meet electricity demand while ensuring grid stability and economic efficiency.1. Basic Principles of Electric Power DispatchingThe fundamental principle of power dispatching is to balance supply and demand by
Echo
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.