Is it safe to use a CO2 fire extinguisher on a high voltage transformer?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Using a carbon dioxide (CO₂) fire extinguisher on a high-voltage transformer is generally safe, but there are important considerations to keep in mind. Here are the key points regarding the safety and precautions:

Safety

Non-Conductive: Carbon dioxide (CO₂) is an inert gas and does not conduct electricity. Therefore, using a CO₂ fire extinguisher to extinguish electrical fires does not increase the risk of electric shock, which is one of its main advantages.

No Residue: CO₂ leaves no residue after extinguishing a fire, preventing secondary contamination or damage to electrical equipment.

Cooling Effect: CO₂ fire extinguishers work by reducing oxygen concentration and providing a cooling effect, which helps to quickly control the fire.

Precautions

Ventilation: CO₂ gas can cause suffocation in enclosed spaces. Ensure there is adequate ventilation when using a CO₂ fire extinguisher to prevent personnel from inhaling excessive amounts of CO₂.

Personal Protective Equipment (PPE): When operating a CO₂ fire extinguisher, wear appropriate personal protective equipment, such as safety glasses and gloves, to prevent frostbite and eye injuries.

Stay Away from Live Parts: Although CO₂ is non-conductive, try to stay away from live electrical parts while extinguishing the fire to avoid accidental contact and potential electric shock.

Identify the Source of the Fire: Ensure that you identify and extinguish the source of the fire, not just the surface flames. Thoroughly extinguishing the source can prevent the fire from reigniting.

Professional Guidance: When dealing with high-voltage transformer fires, it is best to have professional electrical engineers or firefighters present to ensure safe operation.

Alternative Options

Dry Powder Fire Extinguisher: Dry powder fire extinguishers are also effective for electrical fires, but they can leave residue that requires subsequent cleaning.

Dry Ice Fire Extinguisher: Dry ice fire extinguishers use solid CO₂, which is also non-conductive, but use them carefully to avoid frostbite.

Automatic Fire Suppression Systems: For large high-voltage transformers, consider installing automatic fire suppression systems, such as gas-based systems (e.g., FM-200), which can automatically activate to quickly extinguish fires in their early stages.

Summary

Using a carbon dioxide fire extinguisher on a high-voltage transformer is generally safe, but it is crucial to follow the above precautions to ensure the safety of the operators. If possible, seek professional assistance when dealing with high-voltage electrical fires.

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.