Calorific Values of Fuel

Blake
Blake
Field: Power Equipment
0
China

WechatIMG1781.jpeg

When we generate electricity in steam power plant we have to burn fuel like coal, petroleum oil or flammable gases. The fuel can be considered as such a raw material for producing electricity in any kind of thermal power generating plants. So the quality of the fuel used in a thermal power generating plants plays a vital role in that sense. The calorific value of a fuel determines the quality of the fuel. We define the calorific value of a fuel as the amount of heat produced by complete combustion of one unit of the fuel. The unit we consider in this case may be of weight or volume depending on the type of the fuel. In case of solid fuel like coal we use weight unit and in case of liquid and gaseous fuel, we can use volume unit for the purpose.

We define the calorific value of coal as the amount heat in calories generated in the combustion of one gram of coal. So we express the calorific value of coal as calories per gram. We sometimes measure it in kilocalorie per kilogram. In this case, we measure the weight of the coal in kilogram and we express the generated heat in kilocalorie. In case of liquid and gaseous fuel, we can express calorific value in calories per litre or kilocalorie per litre.

Let us look at calorific value of some well known fuels.

  • Lignite has a calorific value of 5000 kcal per kg.

  • Bituminous coal has a calorific value of 7600 kcal per kg.

  • Anthracite coal has a calorific value of 8500 kcal per kg.

  • Heavy oil has a calorific value of 11,000 kcal per kg.

  • Diesel oil has a calorific value of 11,000 kcal per kg.

  • Petrol oil has a calorific value of 11,110 kcal per kg.

  • Natural gas has a calorific value of 560 kcal per cubic metres.

  • Coal gas has a calorific value of 7600 kcal per cubic metres.

calorific value of fuels

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.