Natural Draught and Chimney

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

WechatIMG1891.jpeg

Draught is the pressure difference which causes a flow of air or gases from one point to another point in the boiler system. Draught is required in a boiler system mainly due to two reasons.

  1. To supply sufficient air for completing the combustion.

  2. To remove flue gases from the system after combustion and the heat exchange.

There are two types of draught applied to the boiler system.

  1. The natural draught

  2. The forced draught

We will discuss here in this article about natural draught. The natural draught is always preferred since it does not need any running cost although it has a big initial cost. Natural draught allows natural circulation of air through the boiler system. The natural draught mainly depends upon the height of the chimney.

We try to calculate the required height of the chimney for a required natural draught for a boiler system. For that, we have to go through two basic equations of gaseous pressure. The equations are

Where, “P” is the pressure of air or gas, “ρ” is the density of the air or gas, “g” is the gravitational constant, and “h” is the height of the head.

Here “V” is the volume of the air or gas, “m” is the mass of the gas or air, “T” is the temperature measured in kelvin scale and “R” is the gas constant.
Equation (2) can be rewritten as

During combustion process in the furnace, mainly carbon reacts with oxygen (O2) of the air and forms carbon dioxide (CO2). The volume of the solid carbon compared to the required air for the reaction is negligible. Because of that, we can consider that the volume of air required for combustion is exactly equal to the volume of the flue gases created after combustion if we assume temperature before and after combustion are same. But this is not the actual case. The air entries in the combustion chamber will gain extra volume after combustion due to combustion temperature. The gained volume of the air will be equivalent to the volume of the flue gases created after combustion.


Let us assume, ρo is the density of the air at 0oC or 273 K, and say it is To
Here, P is the pressure of air at 0oC or 273 K, that is at To K.
If we keep, the pressure P as constant, the relation between density and temperature of the air or gases can be written as,

Where, ρa and ρg is the density of the air at temperature Ta and Tg K respectively.
natural draught and chimney

From, equation (1) and (5) we can write the expression of pressure at point “a” outside the chimney, as

The volume of the air at the temperature Tg would be

Let us assume, m kg of air is required to burn 1 kg of carbon then the density of the flue gas would be

The pressure of the flue gas inside the cheimny from equation (1) and (8), would be

The pressure difference between outside and inside of the chimney from equation 96) and (9) would be

Here, “h” is the minimum height of the chimney to be constructed for the draught ΔP. The flue gas will flow upwards through the chimney due to this pressure difference. So, by calculating this pressure difference one can easily calculate the approximate height of the chimney to be constructed. The pressure difference can be represented as a formula for calculating the height of the chimney for a natural draught.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.