Artificial Draught

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is Artificial Draught

The expression of the pressure difference between inside and outside of a chimney shows that it has a term which is the height of the chimney. To achieve sufficient pressure difference between two points or to attain enough natural draught we have to increase the height of the chimney which is not always practical in the view of cost-effectiveness. In those cases, we have to think about artificial draught instead of natural draught. We can achieve artificial draught, mainly with two methods. One gets produced by steam jet, and forced air produces another. Introducing artificial draught one can significantly reduce the height of the chimney to fulfil the same purpose removing flue gasses to the atmosphere.

Induced Draught

Here, an air fan is attached to the base of the chimney or nearer to it. When the fan rotates, it sucks the flue gases from the boiler furnace system. The suction of flue gases from the furnace producers a pressure difference between the outside air and inside flue gases, and which creates a draught. Due to this draught, fresh air enters the furnace. As the draught gets induced due to the suction of gases, we call the method as induced draught. ID fan or induced draught fan sucks the flue gases from the boiler system and pushes to atmosphere through the chimney along its height. In natural draught, the temperature of the flue gases plays a vital role in traveling the gases through the chimney to the atmosphere. But in the case of induced draught, the temperature of flue gas is not an essential parameter. We can utilize the heat energy of the flue gases as much as possible. In induced draught after extracting almost entire heat from the flue gases, the cold flue gases, we remove the gases to the atmosphere forcefully. So we can achieve the purpose of a very tall chimney with much shorter one which is a significant saving of money for the system.

induced draught

Forced Draught

Theoretically induced draught and forced draught are more or less same. The only difference is that in induced draught the suction fan is used and in case of forced draught the blower fan is used. In case of forced draught system, we fit the blower fan before the coal bed. The blower blows the air from the atmosphere to the coal bed and grate where flue gases get created after combustion. The fresh air (preheated) coming to the furnace pushes the flue gases inward. The flue gases then pass through the economiser, air preheater, etc. toward the stack of the chimney. The forced draught creates positive pressure inside the system. Because of that, we should take special care to protect the system from any leakage otherwise the performance of the system gets affected.

forced draught

Balanced Draught

Balanced draught is a combination of forced draught and induced draught. Here we attached blower fans at the entry point of the furnace and induced fans at exit point as well. Here, we utilize benefits of both forced and induced draught. In the balanced draught system, we use forced draught to push the air to the coal, to the grate and later to air preheater. We use the induced draught to withdraw the gases from the economiser and air preheater etc., and then ultimately to discharge the gases to the top of the stack of the chimney.

balanced draught

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.