Understanding Transformer Safety Protection Devices: Oil Cushion, Moisture Absorbers, and More

Rockwell
Rockwell
Field: Manufacturing
China

Transformer Main Body Construction and Safety Protection Devices

A power transformer is equipped with several critical safety protection devices to ensure reliable and safe operation. These components play essential roles in monitoring, protecting, and maintaining the integrity of the transformer under varying operating conditions.

1. Oil Cushion (Conservator Tank)

The oil cushion, also known as the conservator tank, typically has a capacity of approximately 8–10% of the total transformer oil volume. Its primary functions are to accommodate the expansion and contraction of insulating oil due to temperature fluctuations, minimize direct contact between the oil and ambient air, and thereby reduce oil degradation caused by moisture absorption and oxidation. To further enhance protection, moisture absorbers (breathers) are installed on the oil cushion to prevent unfiltered air from entering the transformer during oil volume changes.

2. Moisture Absorber (Breather) and Oil Purifier (Filter)

  • The moisture absorber, commonly referred to as a breather, is filled with desiccants such as silica gel or activated alumina. In many designs, color-changing silica gel is used—appearing blue when dry and turning pink or red when saturated with moisture—providing a visual indication for maintenance, such as drying or replacement of the adsorbent.

  • The oil purifier, also known as a filter or reclaimer, contains similar adsorbent materials (e.g., silica gel, activated alumina) within a cylindrical chamber. As the transformer oil circulates through this unit, the adsorbents remove moisture, organic acids, and oxidation byproducts, helping to maintain oil purity, dielectric strength, and overall longevity.

3. Explosion-Proof Tube (Safety Duct) / Pressure Relief Device

The explosion-proof tube, or safety duct, is mounted on the transformer tank cover and serves to release excessive internal pressure rapidly in the event of a severe internal fault, such as an arc or short circuit, thereby preventing catastrophic tank rupture. In modern large power transformers, this device has largely been replaced by pressure relief valves. These valves are designed to activate automatically when internal pressure exceeds a safe threshold. Upon operation, they not only relieve pressure but also trigger alarm contacts or trip signals to alert operators or initiate circuit breaker tripping, enhancing system protection.

4.Additional Safety and Monitoring Devices

In addition to the above, transformers are also fitted with various other protective and monitoring components, including:

  • Gas protection (Buchholz relay) for detecting internal faults such as arcing or insulation breakdown that generate gas;

  • Temperature gauges to monitor winding and oil temperature;

  • Oil level indicators to provide real-time visualization of oil levels in the conservator.

Together, these safety devices ensure the transformer operates efficiently, reliably, and safely throughout its service life.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.