• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


kVA vs kW: Why Transformers Use kVA for Power Rating

Rockwell
Rockwell
Field: Manufacturing
China

The use of kVA (kilovolt-amperes) instead of kW (kilowatts) to rate transformers stems from the fundamental distinction between real power (kW) and apparent power (kVA) in electrical systems. Transformers transfer electrical energy between circuits via electromagnetic induction, and their kVA rating accounts for both real and reactive power.

Real Power (kW): This is the actual power that performs useful work—such as producing mechanical energy, heat, or light—and reflects the transformer's energy delivery capability.

Reactive Power (kVAR): While not performing useful work, reactive power is essential for maintaining voltage levels and ensuring system stability. Transformers inherently require magnetizing current, which introduces reactive power.

Apparent Power (kVA) is the vector sum of real power (kW) and reactive power (kVAR). Rating transformers in kVA provides a comprehensive measure of their total power-handling capacity. This is particularly important in systems with inductive or capacitive loads—such as motors—that require both real and reactive power.

In summary, specifying transformer ratings in kVA—rather than kW—recognizes the combined effect of real and reactive power. It offers a more accurate representation of the transformer’s ability to handle total power flow, including the reactive component critical to system stability and efficiency.

Give a tip and encourage the author!
Recommended
What causes a transformer to be noisier under no-load conditions?
What causes a transformer to be noisier under no-load conditions?
When a transformer is operating under no-load conditions, it often produces louder noise than under full load. The primary reason is that, with no load on the secondary winding, the primary voltage tends to be slightly higher than nominal. For example, while the rated voltage is typically 10 kV, the actual no-load voltage may reach around 10.5 kV.This elevated voltage increases the magnetic flux density (B) in the core. According to the formula:B = 45 × Et / S(where Et is the designed volts-per-
Noah
11/05/2025
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
When installing an arc suppression coil, it is important to identify the conditions under which the coil should be taken out of service. The arc suppression coil should be disconnected under the following circumstances: When a transformer is being de-energized, the neutral-point disconnector must be opened first before performing any switching operations on the transformer. The energizing sequence is the reverse: the neutral-point disconnector should be closed only after the transformer is energ
Echo
11/05/2025
What fire prevention measures are available for power transformer failures?
What fire prevention measures are available for power transformer failures?
Failures in power transformers are commonly caused by severe overload operation, short circuits due to winding insulation degradation, aging of transformer oil, excessive contact resistance at connections or tap changers, failure of high- or low-voltage fuses to operate during external short circuits, core damage, internal arcing in oil, and lightning strikes.Since transformers are filled with insulating oil, fires can have severe consequences—ranging from oil spraying and ignition to, in extrem
Noah
11/05/2025
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.