What Is a Distribution Transformer? Difference from Power Transformers & Energy Efficiency

Rockwell
Rockwell
Field: Manufacturing
China

1. What Is a Distribution Transformer?

A distribution transformer is a static electrical device in a power distribution system that transfers alternating current (AC) power by transforming voltage and current levels according to the principle of electromagnetic induction.

In certain regions, power transformers with voltage ratings below 35 kV—primarily 10 kV and below—are referred to as "distribution transformers." These are typically installed at substations. In general, a distribution transformer is a static device used in distribution networks to convert AC voltage and current via electromagnetic induction for the purpose of power transmission.

Transformer products in China are generally categorized by voltage level into ultra-high voltage (750 kV and above), extra-high voltage (500 kV), 220–110 kV, and 35 kV and below. Distribution transformers typically refer to power transformers operating in distribution networks with voltage levels of 10–35 kV and capacities up to 6,300 kVA, primarily supplying power directly to end users.

2. What Is the Difference Between Distribution Transformers and Power Transformers?

Distribution transformers are primarily used in power distribution networks to supply electricity to various end users. They typically step down high voltages to levels such as 66 kV, with low-voltage outputs of 380/220 V, 3 kV, 6 kV, or 10 kV. In contrast, power transformers are used to transfer electrical energy between power grids operating at different voltage levels. For example, a regional substation may use a transformer to exchange power between 500 kV and 220 kV grids. These transformers have large capacities and do not directly supply power to end users.

The mainstream energy-efficient distribution transformers include energy-saving oil-immersed transformers and amorphous alloy transformers. Oil-immersed distribution transformers are classified into S9, S11, and S13 series based on their loss characteristics. Compared to the S9 series, the S11 series reduces no-load losses by 20%, while the S13 series further reduces no-load losses by 25% compared to the S11 series.

As China's "energy conservation and consumption reduction" policy deepens, the state actively promotes the development of energy-efficient, low-noise, and intelligent distribution transformer products. High-energy-consuming transformers currently in operation no longer align with industry trends and face technological upgrading or replacement. In the future, they will be gradually phased out and replaced by transformers that are energy-efficient, material-saving, environmentally friendly, and low-noise.

The State Grid Corporation of China has widely adopted S11 series distribution transformers and is progressively promoting the S13 series in urban network upgrades. In the future, S11 and S13 series oil-immersed distribution transformers are expected to completely replace the existing S9 series in operation. Amorphous alloy transformers combine energy efficiency with economic performance. Their most notable feature is extremely low no-load losses—approximately 20% of those in S9 series oil-immersed transformers.

These transformers comply with national industrial policies and power grid energy conservation requirements, offering excellent energy-saving performance. They are particularly suitable for rural power grids and other areas with low load factors.

Currently, amorphous alloy transformers account for only 7%–8% of distribution transformers in operation. Only regions such as Shanghai, Jiangsu, and Zhejiang have adopted them on a large scale. Competition in the distribution transformer market is intense. High raw material costs, coupled with shortcomings in energy-efficiency evaluation systems and market supervision, along with the high initial investment required for energy-saving transformers, present challenges to their widespread adoption.

Give a tip and encourage the author!
Recommended
What causes a transformer to be noisier under no-load conditions?
What causes a transformer to be noisier under no-load conditions?
When a transformer is operating under no-load conditions, it often produces louder noise than under full load. The primary reason is that, with no load on the secondary winding, the primary voltage tends to be slightly higher than nominal. For example, while the rated voltage is typically 10 kV, the actual no-load voltage may reach around 10.5 kV.This elevated voltage increases the magnetic flux density (B) in the core. According to the formula:B = 45 × Et / S(where Et is the designed volts-per-
Noah
11/05/2025
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
Under what circumstances should an arc suppression coil be taken out of service when it is installed?
When installing an arc suppression coil, it is important to identify the conditions under which the coil should be taken out of service. The arc suppression coil should be disconnected under the following circumstances: When a transformer is being de-energized, the neutral-point disconnector must be opened first before performing any switching operations on the transformer. The energizing sequence is the reverse: the neutral-point disconnector should be closed only after the transformer is energ
Echo
11/05/2025
What fire prevention measures are available for power transformer failures?
What fire prevention measures are available for power transformer failures?
Failures in power transformers are commonly caused by severe overload operation, short circuits due to winding insulation degradation, aging of transformer oil, excessive contact resistance at connections or tap changers, failure of high- or low-voltage fuses to operate during external short circuits, core damage, internal arcing in oil, and lightning strikes.Since transformers are filled with insulating oil, fires can have severe consequences—ranging from oil spraying and ignition to, in extrem
Noah
11/05/2025
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
What are the common faults encountered during the operation of power transformer longitudinal differential protection?
Transformer Longitudinal Differential Protection: Common Issues and SolutionsTransformer longitudinal differential protection is the most complex among all component differential protections. Misoperations occasionally occur during operation. According to 1997 statistics from the North China Power Grid for transformers rated 220 kV and above, there were 18 incorrect operations in total, of which 5 were due to longitudinal differential protection—accounting for approximately one-third. Causes of
Felix Spark
11/05/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.