What are some situations where a clamp-on ammeter is more convenient than a voltmeter?

Encyclopedia
Field: Encyclopedia
0
China

In the following situations, a clamp ammeter is more convenient than a voltmeter:

I. In occasions for measuring alternating current

No need to disconnect the circuit

A clamp ammeter can measure alternating current without cutting off the circuit. For example, when checking the current of an electrical device in operation, a clamp ammeter can directly clamp the wire without disconnecting the circuit for wiring operations, avoiding interference to the operation of the device and the possible safety risks brought about by disconnecting the circuit.

In contrast, a voltmeter usually needs to connect the test probes to two test points in the circuit. If it is necessary to measure current, it also needs to be converted by connecting a resistor in series and other methods. The operation is relatively complex and may require disconnecting the circuit.

Quick measurement

The use of a clamp ammeter is very convenient and quick, and the current value can be measured quickly. For example, when troubleshooting a complex electrical system, it is necessary to quickly determine the current situation of each branch. Using a clamp ammeter can complete the measurement in a short time and improve work efficiency.

While using a voltmeter to measure current requires additional calculations and conversions, which takes a long time.

II. In cases where it is difficult to approach the test points

Limited space

In some places with narrow space or difficult access, such as inside a distribution box or on a cable tray, a clamp ammeter can easily clamp the wire for measurement. For example, in a narrow distribution box where the wires are closely arranged, it may be very difficult to use a voltmeter for measurement, while a clamp ammeter can directly clamp the wire outside for measurement.

The test probes of a voltmeter may not be able to conveniently contact the test points, or the operation is inconvenient in cases of limited space.

Working at heights

When it is necessary to measure electrical equipment at heights, a clamp ammeter is safer and more convenient. For example, when measuring the current on an overhead line, a clamp ammeter can directly clamp the wire on the ground for measurement without climbing up for wiring operations, reducing the operation risk.

While using a voltmeter for measurement may require climbing a pole or using other climbing equipment, the operation is complex and there are safety hazards.

III. In cases of measuring large currents

High-precision measurement

For measuring large currents, clamp ammeters usually have higher precision and measurement range. For example, in industrial production, the operating current of some large equipment may be as high as hundreds of amperes or even thousands of amperes. Using a clamp ammeter can accurately measure these large current values.

When a voltmeter measures large currents, it needs to be converted through devices such as shunts, which is prone to introduce errors, and may not be accurate enough for measuring large currents.

Safe and reliable

When measuring large currents, using a clamp ammeter can avoid direct contact with high-current lines and reduce the risk of electric shock. For example, when measuring the output current of a power transformer, the current is relatively large. If a voltmeter is used for measurement, complex wiring operations may be required, increasing the possibility of electric shock.

The insulation performance of a clamp ammeter is better, and it can measure large currents under the premise of ensuring safety.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.