Why does the resistance of a galvanometer increase over time?

Encyclopedia
Field: Encyclopedia
0
China

A galvanometer is an instrument used to detect and measure small currents. Over time, the resistance of a galvanometer may increase due to several reasons:

1. Increased Contact Resistance

  • Oxidation of Contacts: The contacts in a galvanometer, such as terminals and switches, can oxidize due to exposure to oxygen in the air, forming an oxide layer. This oxide layer increases the contact resistance.

  • Dirt and Dust Accumulation: Over time, dust and dirt can accumulate on the contacts, further increasing the contact resistance.

2. Material Aging

  • Aging of Wires: The internal wires of the galvanometer may age over time, leading to an increase in their resistance. Aging can be due to physical degradation or chemical changes in the material.

  • Aging of Components: Other components in the galvanometer, such as resistors and capacitors, may also age over time, degrading their performance and affecting the overall resistance.

3. Environmental Factors

  • Temperature Changes: Temperature variations can affect the resistivity of materials. High temperatures can increase the resistance of wires and other components.

  • Humidity: High humidity environments can cause corrosion of metal parts, increasing contact resistance.

4. Mechanical Wear

  • Wear and Deformation: Over time, mechanical parts inside the galvanometer, such as springs and pointers, can wear out or deform, affecting their contact performance and increasing resistance.

  • Loosening: Loose mechanical parts can also lead to poor contact, increasing resistance.

5. Internal Contamination

Internal Pollutants: Internal pollutants, such as oil and dust, can accumulate inside the galvanometer, increasing internal resistance.

6. Degradation of Magnetic Materials

Degradation of Magnetic Materials: The magnetic materials in the galvanometer, such as permanent magnets, can degrade over time, leading to a reduction in magnetic field strength and affecting the sensitivity and performance of the galvanometer.

Solutions

To reduce the increase in resistance of a galvanometer, the following measures can be taken:

  • Regular Cleaning: Regularly clean the contacts and internal components of the galvanometer to remove oxidation and dirt.

  • Moisture and Corrosion Protection: Keep the galvanometer in a dry and well-ventilated environment to avoid high humidity and corrosive gases.

  • Replace Aging Components: Timely replace aged wires, resistors, and other components.

  • Calibration and Maintenance: Perform regular calibration and maintenance to ensure the stable performance of the galvanometer.

Protective Measures: Use dust covers, seals, and other protective measures to reduce the impact of external pollutants.

Summary

The increase in the resistance of a galvanometer over time is mainly due to increased contact resistance, material aging, environmental factors, mechanical wear, internal contamination, and degradation of magnetic materials. By performing regular maintenance and care, these issues can be effectively reduced, extending the lifespan of the galvanometer.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.