What is the process for measuring the hysteresis loop of a material like iron?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Process for Measuring the Hysteresis Loop of Materials like Iron

Measuring the hysteresis loop (Hysteresis Loop) of materials such as iron is an important experimental process used to study the magnetic properties of these materials. The hysteresis loop provides crucial information about energy loss, coercivity, and remanence during the magnetization and demagnetization processes. Below is a detailed procedure for measuring the hysteresis loop:

Experimental Equipment

  • Power Supply: Provides a stable DC or AC power source.

  • Magnetizing Coil: Wrapped around the sample to generate a magnetic field.

  • Hall Effect Sensor: Used to measure the magnetic induction B in the sample.

  • Ammeter: Used to measure the current I through the magnetizing coil.

  • Data Acquisition System: Used to record and process experimental data.

  • Sample Holder: Fixes the sample to ensure its position remains stable.

Experimental Steps

Prepare the Sample:

Secure the test material (such as an iron rod or iron sheet) in the sample holder, ensuring its position is stable.

Set Up the Magnetizing Coil:

Wrap the magnetizing coil tightly around the sample, ensuring it is evenly distributed.

Connect the Circuit:

Connect the magnetizing coil to the power supply and ammeter, ensuring the circuit connections are correct.

Place the Hall effect sensor at an appropriate position on the sample to measure the magnetic induction B.

Calibrate the Equipment:

Calibrate the Hall effect sensor and ammeter to ensure accurate measurements.

Initial Demagnetization:

Perform initial demagnetization of the sample to ensure it is in a zero-magnetized state. This can be achieved by applying a reverse magnetic field or heating the sample above its Curie point and then cooling it.

Gradually Increase the Magnetic Field:

Gradually increase the current I through the magnetizing coil and record the magnetic induction B at each current value.Use the data acquisition system to record the corresponding values of I and B.

Gradually Decrease the Magnetic Field:

Gradually decrease the current I through the magnetizing coil and record the magnetic induction B at each current value.Continue recording the corresponding values of I and 

B until the current returns to zero.

Repeat Measurements:

To obtain more accurate data, repeat the above steps multiple times to ensure consistency and reliability of the data.

Plot the Hysteresis Loop:

Use the recorded data to plot the relationship between magnetic induction B and magnetic field strength H.

The magnetic field strength H can be calculated using the following formula: H= NI/L

where:

  • N is the number of turns in the magnetizing coil

  • I is the current through the magnetizing coil

  • L is the average length of the magnetizing coil

Data Analysis

Determine Remanence Br:

Remanence Br is the magnetic induction remaining in the material when the magnetic field strength H is zero.

Determine Coercivity Hc :

Coercivity Hc  is the reverse magnetic field strength required to reduce the magnetic induction B from its positive maximum value to zero.

Calculate Hysteresis Loss:

Hysteresis loss can be estimated by calculating the area enclosed by the hysteresis loop. The hysteresis loss Ph can be expressed using the following formula: P h =f⋅Area of the hysteresis loop where:

f is the frequency (unit: hertz, Hz)

Precautions

  • Temperature Control: Maintain a constant temperature during the experiment to avoid the influence of temperature changes on the measurement results.

  • Data Recording: Ensure accurate and complete data recording to avoid omissions or errors.

  • Equipment Calibration: Regularly calibrate the experimental equipment to ensure the reliability of the measurement results.

By following these steps, the hysteresis loop of materials like iron can be effectively measured, and important magnetic properties can be obtained. These parameters are crucial for material selection and application.

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.